AIR FLOW DATA - 60 Hz MODELS - 230 VOLT
Models
Blower
Motor Speed
CFM
1
@ External Static Pressure - IWC
0.10 0.20 0.30 0.40 0.50 0.60 0.70
230 Volt
AHE18B3XH21
High #5
1075 1041 1003 970 930 885 842
Med High #4
895 845 808 767 709 647 561
Med #3
663 618 557 490 348 267 192
Med Low #2
629 468 356 197 175 68 23
Low #1
629 468 356 197 175 68 23
AHE24B3XH21
High #5
1156 1120 1093 1056 1014 951 862
Med High #4
1021 987 952 918 873 836 787
Med #3
829 789 754 698 654 585 532
Med Low #2
681 621 575 496 435 336 262
Low #1
598 503 437 340 259 203 74
AHE30B3XH21
High #5
1156 1120 1093 1056 1014 951 862
Med High #4
1021 987 952 918 873 836 787
Med #3
829 789 754 698 654 585 532
Med Low #2
681 621 575 496 435 336 262
Low #1
598 503 437 340 259 203 74
AHE36C3XH21
High #5
1465 1415 1360 1307 1246 1183 1118
Med High #4
1260 1204 1142 1075 1008 946 876
Med #3
1088 1022 939 862 782 721 626
Med Low #2
998 810 717 630 562 493 444
Low #1
903 707 411 323 265 152 NA
AHE42D3XH21
High #5
1632 1589 1542 1494 1446 1391 1335
Med High #4
1430 1390 1346 1294 1238 1168 960
Med #3
1238 1198 1145 1082 993 908 805
Med Low #2
1118 1020 947 851 734 666 563
Low #1
998 772 477 418 349 NA NA
AHE48D3XH21
High #5
1861 1823 1787 1750 1708 1666 1620
Med High #4
1674 1640 1599 1562 1516 1472 1432
Med #3
1442 1405 1358 1311 1262 1197 1108
Med Low #2
1257 1220 1163 1103 1031 942 864
Low #1
1153 1031 967 867 764 718 633
AHE60D3XH21
High #5
2091 2053 2016 1975 1937 1906 1869
Med High #4
1903 1868 1832 1791 1748 1703 1660
Med #3
1634 1598 1562 1516 1468 1422 1350
Med Low #2
1447 1404 1361 1318 1257 1164 1092
Low #1
1268 1203 1148 1073 978 907 839
1. Dry coil conditions only, tested without filters.
Air handler units are CSA listed to UL 1995/CSA C22.2 236-05 up to 0.30" w.c. external static pressure, including air filter, wet coil, and largest kW size heater, unless
otherwise noted.
Operation not recommended in shaded areas.