Yeoman YM-CL8MF Stove User Manual


 
6
USER INSTRUCTIONS
Do not burn construction timber, painted, impregnated
/ treated wood, manufactured board products or pallet
wood.
3.2 Solid fuel
Burn only anthracite or manufactured briquette smokeless
fuels listed as suitable for use with closed heating
appliances.
Do not burn bituminous coal, ‘petro-coke’ or other
petroleum based fuels as this will invalidate the product
guarantee.
3.3 Fuel consumption
As tested at nominal heat output to the requirements of EN
13240: 2001 for intermittent operation:
Description
Fuel Consumption
Kg/hour
Wood
Kg/hour
Briquette
Smokeless fuel
Yeoman CL 3 1.4 0.7
Yeoman CL 5 1.5 0.7
Yeoman CL 8 2.8 1.3
3.4 For advice on suitable solid fuels contact your local
approved coal merchant*.
A number of factors can affect the performance of the
appliance (see User Instructions, Section 6).
4. LIGHTING THE APPLIANCE
4.1 For best results:
Set air controls (see Diagram 4).
PR8722
Airwash: Fully Open
Primary Air: Fully Open
Place firelighters or paper and dry kindling wood on the
grate.
Light the paper or firelighters (see Diagram 5).
Leave the door slightly open as the fire establishes and
the glass warms to avoid the build-up of condensation.
Add larger pieces of wood. Too many logs may smother
the fire.
Do not load fuel above the log guard and the secondary
combustion inlets at the back of the firebox (see
Diagram 6).
PR8725
Air Inlets
Log Guard
Wood Stove