12
TECHNICAL SPECIFICATION
YEOMAN
1. STANDARD FEATURES
• Primary Air (under grate air for full multi-fuel use).
• Airwash (for wood burning / clean glass).
• Preset Secondary Air control (to ensure complete burning of
flue gases).
• Riddling grate system for clean de-ashing (multi-fuel only).
• Top or rear flue exit option.
2. PACKING LIST
• User & Installer Instructions
• Guarantee card
• Pair leather gloves
• Fire bricks
• Ashpan (multi-fuel only)
• Ashpan tool (multi-fuel only)
• Riddling tool (multi-fuel only)
Model
Yeoman CL3 - YM-CL3MF
Yeoman CL5 - YM-CL5W / YM-CL5MF
Yeoman CL8 - YM-CL8W / YM-CL8MF
Yeoman CL3
Yeoman CL5
Yeoman CL8
Nominal Heat Output
Wood kW 3.75 4.9 8
Solid Fuel kW 3.75 4.9 8.6
Flue Draft at Nominal Heat Output All Fuels
mm Wg 1.25 1.25 1.25
inch Wg 0.05 0.05 0.05
Flue Gas Mass Flow
Wood g/s 3.8 2.6 7.0
Solid Fuel g/s 2.9 3.2 7.3
Flue Gas Temperature at Spigot/Socket
Wood °C 408 369 446
Solid Fuel °C 408 369 446
Flue Outlet Size (Top or Rear Option)
mm 125 125 150
inch 5 5 6
Minimum Hearth Type Required Constructional = CH CH CH CH
Weight kg 76 120 140
Recommended Fuels
Wood
Seasoned wood (less than 20% moisture content)
Solid Fuels
Briquette smokeless fuel suitable for closed appliances.
(Ancit - Phurnacite - Taybrite - Homefire ovals)
As tested to the requirements of EN 13240 for intermittent operation.