4
USER INSTRUCTIONS
1. GENERAL POINTS
1.1 Before use of this appliance please read these
instructions fully.
The appliance must be fitted by a registered installer
*
, or
approved by your local building control officer.
1.2 All local regulations, including those referring to national
and European Standards need to be complied with when
installing the appliance.
1.3 Only use for domestic heating in accordance with these
operating instructions.
1.4 You must burn only approved fuels. Do not use with liquid
fuels or as an incinerator.
1.5 Appliance surfaces become very hot when in use. Use
a suitable fireguard if young children, elderly or infirm
persons are present.
Stovax offer firescreens, sparkguards and hearthgate systems
for protection
‡
. Your Yeoman retailer can advise you about
these products.
1.6 Do not place photographs, TV’s, paintings, porcelain or
other combustible items on the wall or near the appliance.
Exposure to hot temperatures will cause damage.
1.7 Extractor fans or cooker hoods must not be placed in the
same room or space as this can cause appliance to emit
fumes into the room.
1.8 Do not obstruct inside or outside ventilation required for
the safe use of this appliance.
1.9 Do not make unauthorised changes to the appliance.
1.10 The chimney must be swept at least once a year (see User
Instructions, Section 13).
1.11 Do not connect, or share, the same flue or chimney
system with another appliance.
1.12 This appliance is designed to be used with the doors shut.
SERIAL NUMBER
1.13 This number is required when ordering spare parts or
making warranty claims. It is found on the appliance data
plate.
Data Plate
PR8745
The data plate is found on a swing out data plate located
on the back of the stove on the left hand side (see
Diagram 1).
AIR CONTROLS
Triple Air Systems
This Yeoman appliance has a triple air system, providing
cleaner burning and greater efficiency and control (see
Diagram 2).
1) Airwash - air drawn over the window cleans the glass.
The source of Primary Combustion air when burning wood.
2) Primary Air - for use with solid fuel and when lighting
wood fires.
3) Cleanburn - secondary air is preheated through a heat
exchanger to combust unburned hydrocarbons, providing a
cleaner and more efficient burn.
PR8702
For Air Controls see the diagram over.
Use the tool provided to operate the air controls.
Do not place tool on hot surfaces (e.g. top of stove).
‡In the U.K. these products must conform to the latest
edition of BS 8423, Fireguards for use with solid fuel
appliances.
If appliance is operating unattended they must conform to
the latest edition of BS 3248.
*Registered on the Competent Persons Scheme (GB only)
see page 26 / INFO (Republic of Ireland).