Windsor CBE20 Vacuum Cleaner User Manual


 
MAINTENANCE-SHUNT ADJUSTMENT
86306300 CHARIOT BURNISHER 11/09/07
4-10
SHUNT ADJUSTMENT
This pad pressure meter adjustment is factory set.
Over the course of time it may become necessary to
adjust this setting using the slotted connection on
the shunt.
Check the amp range when nuisance tripping of the
pad motor controller indicates that the shunt may be
out of adjustment.
1. Connect a DC ampere meter to the positive
battery lead. Running the machine with a pad,
lower the pad to the floor until it is operating at
60±5 amps.
2. Moving the wire in the slot, adjust the pad
pressure meter until the needle sets at the line
between the blue and red areas.
APPROX. AMP RANGE
60
0
RED
GREEN
GREEN