Windsor 10086130 Vacuum Cleaner User Manual


 
MAINTENANCE-SCRUB DECK
86292490 VOYAGER DUO 08/20/07
4-9
ACTUATOR SCRUB DECK
REMOVAL/REPLACEMENT
FOR SAFETY: Before leaving or servicing
machine, stop on a level surface. Turn off
machine.
1. Lower scrub deck. Remove the front cover and
raise recovery tank.
2. Disconnect electrical connector.
3. Remove the clevis pin retaining the bottom of
the acutator.
4. Remove the clevis pin retaining the top of the
acutator.
5. Reverse for re-installation.
SCRUB DECK ACTUATOR ADJUSTMENT
The actuator will need to be adjusted when
replaced.
To adjust the actuator:
1. While holding actuator barrel to prevent it from
spinning, apply power to the actuator such that it
is fully extended. Positive power to white wire,
and negative/ground to black. Limit switch
within actuator will stop it.
2. With actuator fully extended, attach to the top
bracket.
3. At the bottom mount align the mounting hole
with the center of the slot, turn the barrel in or
out enough to align connection to bracket.
4. Connect actuator electrical plug.
5. Check travel of actuator during operation.