The 1F51-619 low voltage thermostat is designed to
operate with the White-Rodgers 8A18Z-1
Evaporative Cooler Control. For versatility, the
thermostat sub-base has a System Switch that lets
you select VENT, COOL, or OFF positions, while the
Fan Switch offers the selection of LOW or HIGH fan
speed.
____________________________________SPECIFICATIONS_____________________________________
Electrical Rating: 30V.A.C. Max.
Switch Action: SPST-Sealed Mercury Contacts
close on temperature rise.
Temperature Scale Range: 1 to 5 (Cooler to Warmer)
Differential: 1°F
Dimensions: 3¼” x 4½” x 1
________________________________________SAFETY_________________________________________
Installation of this equipment should be done by an experienced
service technician.
CAUTION: To prevent electrical shock and equipment
damage, disconnect electrical power to system at main fuse
or circuit breaker box, until installation is complete.
WARNING: Do not exceed the specification ratings on this
control. Check the manufacturer’s information
supplied with the associated product.
Improper connections could cause shock
or fire hazard.
All wiring must conform to local and
national electrical codes and ordinances.
Rough handling, tampering or distorting
components of control, could cause the
control to malfunction.
_____________________________SELECTING THERMOSTAT LOCATION__________________________
The proper location of the room thermostat is most
important to insure that it will provide a comfortable
home temperature. Observe the following general rules
when selecting a location:
1. Locate it about 5 ft. above the floor.
2. Install it on a partitioning wall, not on an outside wall.
3.
Never expose it to direct light from lamps, sun,
fireplaces, or any temperature radiating equipment.
4.
Avoid locations close to doors that lead outside,
windows or adjoining outside walls.
5.
Avoid locations close to air registers, or in the direct
path of air from them.
6.
Make sure there are no pipes or duct work in that
part of the wall chosen for the thermostat location.
7.
Never locate it in a room that is warmer or cooler
than the rest of the home.
8.
Avoid location with lack of air circulation, such as
behind doors or alcoves.
9. The living or dining room is normally a good location
provided there is no cooking range or refrigerator on
opposite side of wall.
INSTALLATION INSTRUCTIONS
1F51-619
LOW VOLTAGE
EVAPORATIVE COOLER
THERMOSTAT