White Rodgers 1F97-1277 Thermostat User Manual


 
9
Enter the Heating ProgramEnter the Heating Program
Enter the Heating ProgramEnter the Heating Program
Enter the Heating Program
1) Press the Menu button and then press Set Schedule.
Press SYSTEM button to select either "
HeaHea
HeaHea
Hea
tt
tt
t" or "
CoolCool
CoolCool
Cool" in
the system switch area indicating the active mode being
programmed. You can switch to the other mode by
pressing the system switch at any time.
2) The top of the display will show the day(s) being pro-
grammed. The time and set at temperature are also
displayed. "
MorMor
MorMor
Mor
ningning
ningning
ning" will also be displayed to indicate
the period.
3) Press
or key to change the temperature to your
selected temperature for the 1st heating period (Morning).
4) Press
or key to adjust the start time for period.
The time will change in 15 minute increments.
5) Press
FF
FF
F
AN AN
AN AN
AN to select
AA
AA
A
uto uto
uto uto
uto or
PrPr
PrPr
Pr
oo
oo
o
gg
gg
g.
6) After you have set the time and the temperature for the
period to begin, press Set Schedule to advance to the
next program period.
7) Repeat steps 2 through 6 until all of the program times
and temperatures are set for all program periods on
that day.
8) Press "Advance Day" to change to the next day and
repeat steps 2 through 8.
9) When programming is complete and all of the times and
temperatures match your desired heating schedule, press
Run Schedule. The thermostat will now run your program.
Enter the Cooling ProgramEnter the Cooling Program
Enter the Cooling ProgramEnter the Cooling Program
Enter the Cooling Program
1) Press the SYSTEM
button until the Cool icon appears.
2) Follow
Enter HeaEnter Hea
Enter HeaEnter Hea
Enter Hea
ting Prting Pr
ting Prting Pr
ting Pr
oo
oo
o
gg
gg
g
rr
rr
r
amam
amam
am instructions for entering
cooling times and temperatures.
PROGRAMMINGPROGRAMMING
PROGRAMMINGPROGRAMMING
PROGRAMMING
Fill in the blank schedule on the next page then:
Automatic ScheduleAutomatic Schedule
Automatic ScheduleAutomatic Schedule
Automatic Schedule
This feature provides a method to program every day with
the most popular time and temperature profile using one key
press. For this feature to be available, the Auto schedule
options (
AS CoolAS Cool
AS CoolAS Cool
AS Cool or
AS HeatAS Heat
AS HeatAS Heat
AS Heat) should be set on in the
installer configuration.
Select the desired “Comfort Temperature” in the setpoint.
When the
Auto ScheduleAuto Schedule
Auto ScheduleAuto Schedule
Auto Schedule touch key is pressed, it will start
flashing indicating that it is now ready to insert the displayed
temperature setpoint as the “Comfort Temperature” for the
selected system mode currently in (Heat/Cool). A second
press of the
Auto ScheduleAuto Schedule
Auto ScheduleAuto Schedule
Auto Schedule touch key will complete the
process. A 6
o
F setback temperature will also be inserted for
the night step. Once it is done, the touch key display
AutoAuto
AutoAuto
Auto
ScheduleSchedule
ScheduleSchedule
Schedule will disappear disabling any further operation of
Auto ScheduleAuto Schedule
Auto ScheduleAuto Schedule
Auto Schedule touch key. If desired it can be enabled again
in the installer configuration menu.
Entering Fan ProgramEntering Fan Program
Entering Fan ProgramEntering Fan Program
Entering Fan Program
This key is used to select
F F
F F
F
ANAN
ANAN
AN
AA
AA
A
utouto
utouto
uto operation (fan energized
with a call for cool but not on with a call for heat) to
FF
FF
F
ANAN
ANAN
AN
OnOn
OnOn
On
(fan on continuous) or
FF
FF
F
AN PRAN PR
AN PRAN PR
AN PR
OGOG
OGOG
OG (fan programmed to cycle
fixed time automatically). Each press of the
FF
FF
F
ANAN
ANAN
AN touch key
will change the mode from
AA
AA
A
utouto
utouto
uto to
On On
On On
On to
PrPr
PrPr
Pr
oo
oo
o
gg
gg
g.
FF
FF
F
ANAN
ANAN
AN
AA
AA
A
utouto
utouto
uto or
FF
FF
F
AN OnAN On
AN OnAN On
AN On or
FF
FF
F
AN On PrAN On Pr
AN On PrAN On Pr
AN On Pr
oo
oo
o
gg
gg
g will display in the run mode for as
long as the fan is in that position. When
FF
FF
F
AN PrAN Pr
AN PrAN Pr
AN Pr
oo
oo
o
gg
gg
g position is
selected and the system key is in the
Cool,Cool,
Cool,Cool,
Cool,
Hea Hea
Hea Hea
Hea
tt
tt
t or
AA
AA
A
utouto
utouto
uto
mode the circulator blower (fan) will cycle ON for 10 minutes,
OFF for 20 minutes when the thermostat has not called for
cooling or heating for the past 60 minutes.
To improve indoor air quality, the system circulator can be
programmed to run during any program time period by
touching the
FanFan
FanFan
Fan touch key in the appropriate program time
period when in the
MenuMenu
MenuMenu
Menu mode for that particular day.
The display shall indicate
ProgProg
ProgProg
Prog (under the
FanFan
FanFan
Fan icon) when in
Menu mode and the fan is programmed to come on during
that time.
In the menu mode, each time the fan key is pressed, the fan
operation and display will change from
FAN AutoFAN Auto
FAN AutoFAN Auto
FAN Auto to
FANFAN
FANFAN
FAN
ProgProg
ProgProg
Prog. The display shall indicate
FAN On ProgFAN On Prog
FAN On ProgFAN On Prog
FAN On Prog when in run
mode and the fan is programmed to run for that particular
time period.
When in
Run ScheduleRun Schedule
Run ScheduleRun Schedule
Run Schedule mode and the
FAN FAN
FAN FAN
FAN touch key is
pressed, it will override the schedule, and the display and fan
operation shall change to
FAN AutoFAN Auto
FAN AutoFAN Auto
FAN Auto and the fan is stopped.
Further key depression will change it to
FAN OnFAN On
FAN OnFAN On
FAN On (continuous
blower on) and to
FAN ProgFAN Prog
FAN ProgFAN Prog
FAN Prog (cycling 10 minutes on and 20
minutes off if there is no call for heat or cool for 60 minutes).
The
Run ScheduleRun Schedule
Run ScheduleRun Schedule
Run Schedule touch key will also be indicated, meaning
that it is an override on the scheduled program. The override
will last until next schedule comes up or the
Run ScheduleRun Schedule
Run ScheduleRun Schedule
Run Schedule
touch key is depressed.