White Rodgers 1F97-0671 Thermostat User Manual


 
5
INSTALLER/CONFIGURATION MENU
Press and hold the Menu button for at least 5 seconds. The display will show item #1 in the table below. Press Menu to ad-
vance to the next menu item. Press
or to change a menu item options.
INSTALLER/CONFIGURATION MENU
MENU
REF.
PRESS
BUTTON
DISPLAYED
(FACTORY DE-
FAULT)
Press
or to
select from listed op-
tions
COMMENTS
1 MENU (GAS) ELE GAS setting: furnace controls the blower
ELE setting: thermostat controls the blower
2 MENU CS (3) 0, 1, 2, 4, 5, 6 Selects Cool Savings
Value 1 (low) to 6 (high),
Value 0 disables feature
3 MENU E (On) OFF Selects Energy Management Recovery (EMR)
On or OFF.
4 MENU CR Heat (ME) SL, FA Adjustable Anticipation:
Selects heating cycle rate for MS or SS in #1 only
5 MENU CR Cool (ME) SL, FA Adjustable Anticipation:
Selects the cycle rate for cooling
6 MENU CL (OFF) CL On Compressor Lockout Time
7 MENU Cool Off, Heat Auto Heat Auto Cool Off,
Heat Off with Fan icon,
Heat Off without Fan icon
Cool Off, Auto Off
System Mode Confi guration
with Automatic Changeover capability
8 MENU dL (On) dL OFF Selects Display Light On or OFF
9 MENU 0
(current temperature)
1 HI, 2 HI, 3HI, 4 HI,
1 LO, 2 LO, 3 LO, 4 LO
Adjustable Ambient Temperature Display
10 MENU °F °C Selects Fahrenheit/Celsius Temperature Display
11 MENU (On) b OFF May select Beeper OFF to stop audible
key feedback
12 MENU P (7) 3, 0 Defaults 7-day programming (P7) but non-
programmable (0) or 5/1/1 programming (P3)
is available on most models.
13 MENU PS (4) 2 Selects Program periods per day:
4 = Morn, Day, Eve, Night
2 = Day, Night
14 MENU Heat AS (On) OFF Automatic Schedule for heat mode
15 MENU Cool AS (On) OFF Automatic Schedule for cool mode
16 MENU Remote (OFF) On Selects Remote Sensor On/OFF
MENU Remote
(In)
Outdoor Selects Remote Sensor to outdoor
NA is Remote Sensor OFF
MENU Indoor Loc
(On)
OFF Selects Local Sensor (in thermostat) to OFF.
N/A if Remote is selected to Outdoor
17 MENU dS (On) Off Selects Automatic Daylight Saving Time option
18 MENU (OFF)
Keypad Lockout
L, P, Limit Selects one of 3 Keypad Lockout confi gurations
L - Total Keypad Lockout
P - Partial Keypad Lockout
(Up and Keys still work)
Limit - Limited Temperature RANGE
MENU (000)
Keypad Lockout
1-999 Selects personal lockout code. 000 is NOT A
VALID CODE.
19 MENU L Heat
(99)
L 62 to L 98 Selects Limited HEAT Range Temperature
20 MENU L Cool
(45)