ADJUSTABLE HEATING AND COOLING
CYCLE TIMES (ANTICIPATION) — If the
heating/cooling system is turning on and off
too often (short cycles) or not often enough
(long cycles), you may want to adjust the
anticipation setting.
A cooling anticipation setting of less
than 10 may cause decreased compres-
sor life.
To adjust anticipation, press
SET
CLOCK
and
ADV
DAY
at the same time. The display will show
HEAT 8 (this is the factory preprogrammed
heating anticipation setting). You may se-
lect any anticipation setting from 4 to 40.
If the heat cycles are too short, press
TIME
FWD
to increase the cycle time. If the heat cycles
are too long, press
TIME
BACK
to decrease the
cycle time. To set cooling anticipation, press
SET
CLOCK
and
ADV
DAY
at the same time again. The
display will show COOL 14 (factory prepro-
grammed cooling anticipation). Use the
TIME
FWD
and
TIME
BACK
buttons to adjust anticipation. Press
RUN
PRGM
to return to your program.
LOW BATTERY INDICATOR — The word
BATTERY will flash on the display if the 9
volt alkaline battery is low and should be
replaced.