CONFIGURATION MENU
Non- Displayed Press or
Program- Program- Press (Factory to select from
mable mable Button Default) listed options Comments
1 1 MS 2 HP 1, HP 2, SS 1 Selects Multi-Stage (MS 2, No Heat Pump), Heat Pump 1
(HP 1, 1 compressor), Heat Pump 2 (HP 2, 2 compressor
or 2 speed compressor), or Single Stage.
22
(ELE) GAS GAS setting: furnace controls blower.
ELE setting: thermostat controls blower.
33
Days, (7) P5-1-1 or 0 Programs per week. (0 = non-programmable)
4NA
PS (4) 2 Program periods per day.
4 = Morning, Day, Evening, Night
2 = Day, Night
54
Cool-Off- Cool-Off-Heat, System switch configuration in non heat pump mode.
Heat-Auto Off-Heat, Cool-Off
Cool-Off-Heat- Cool-Off-Heat-Emer, System switch configuration, heat pump mode.
Emer-Auto Off-Heat-Emer, Cool-Off
6NA
E (On) OFF Selects Energy Management Recovery, E (with programming option on)
75 Cr, Heat (FA) SL Selects Adjustable Anticipation, cycle rate, Heat
86
Cr, Cool (FA) SL Selects Adjustable Anticipation, cycle rate, Cool
97
Cr/AU, Emer (FA) SL Selects Adjustable Anticipation, cycle rate auxiliary, (This item is
only to appear if HP 1 or HP 2 is selected above).
10 8
CL (OFF) On Selects Compressor Lockout.
11 9
dL (On) OFF Selects Continuous Display backlight & intensity.
12 10 dL (LO) HI Selects Backlight Intensity.
13 11
0 4, LO to 4, HI Selects Adjustable Ambient Temperature Display [range -4 (LO) to
+4 (HI)].
14 12
°F °C Selects °F/°C Display (temperature units in Fahrenheit or Celsius).
15 13
b (On) OFF Selects audible Beeper On/Off.
16 14
dS (On) OFF Selects Daylight Saving Time calculation.
17 15 AS, Heat (On) OFF Selects Automatic Schedule for comfort temperature Programming,
heat mode.
18 16
AS, Cool (On) OFF Selects Automatic Schedule for comfort temperature Programming,
cool mode.
19 17
CS, (OFF) 1-2-3-4-5-6 Selects Cool Saving Feature & amount.
Cool Savings
20 18
HL, Heat (99) 62-98 TEMPERATURE LIMIT, HEAT (max. heat set point).
21 19
LL, Cool (45) 46-82 TEMPERATURE LIMIT, COOL (min. cool set point).
22 20
OFF, L (total), P (partial), Selects Keypad Lockout.
Keypad Lockout Temperature Limit
(limited temperature range)
000 001-999 Selects Keypad Lockout Combination (active only if keypad Lockout
is selected).
23 21
FS, Heat (On) OFF Fast second stage of heat (not available if SS1 is selected above).
24 22
FS, Cool (On) OFF Fast second stage of cool (not available if SS1 or HP1 is selected
above).
25 23
Remote (OFF) On Remote temperature sensor, enable/disable.
In, Remote Outdoor Remote Remote temperature sensor (Indoor/Outdoor).
LS (On) OFF Local temp. Sensor enable/disable (only when Indoor Remote is
selected On).
26 24
dF (5) 5-50 Selects Dual Fuel Feature & set point (in Fahrenheit) (applicable only
when HP1 or HP2 is selected).
Cd (60) 0-99 Selects Compressor delay in seconds (only when dF is selected >5).
27 25
Change Filter On Selects Change filter feature
(OFF)
200 Hours 25-1975 (in increments Change filter, duration hours.
of 25 hours)
INSTALLER/CONFIGURATION MENU
To enter the menu: Press the Menu touch key. Press and hold for 5 seconds the Installer Config touch key. This displays
menu item #1 in the table below. Press
to advance to the next menu item or to return to a previous menu item. Press
or to change a menu item.
Menu
Reference
Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27