White Rodgers 1F95-0477 Thermostat User Manual


 
6
INSTALLER/CONFIGURATION MENU
To enter the Configuration Menu, SYSTEM must be set to HEAT, COOL, Em or AUTO. Press the Menu button for at least 5
seconds. The display will show item #1 in the table below. Press Menu button to advance to the next menu item. Press
or
to change an item option.
INSTALLER/CONFIGURATION MENU
MENU
SCREEN
NUMBER
MS2/
SS1
HP1/
HP2
DISPLAYED
(FACTORY DEFAULT)
Press
or to
select from listed options
COMMENTS
01
(OFF) Lk L Selects Keypad Lockout.
(Not available on earlier models)
02
(000) Lk 001 to 999 Selects Keypad lockout combination number
03
(MS 2) SS1, HP1, HP2 Selects Multi-Stage (MS 2 No Heat Pump),
Heat Pump 1 (HP 1, 1 compressor),
or Single Stage (SS 1), Heat Pump 2 (HP 2, 2
compressor or 2 speed compressor)
04
(GAS) ELE Select Gas or Electric heat
(ELE) GAS
05
(0) CS 1, 2, 3, 4, 5, 6 Selects Cool Savings
Value 1 (low) to 6 (high), Value 0 Disables Feature
06
(On) E OFF Selects Energy Management Recovery (EMR)
On or OFF.
07
(ME)
CR Heat
SL, FA Adjustable Anticipation:
Selects heating cycle rate for MS or SS
08
(ME)
CR Cool
SL, FA Adjustable Anticipation: Selects the cycle
rate for cooling (only when MS2 or SS1
is selected in item 1)
09
(ME)
CR Heat Pump
SL, FA Adjustable Anticipation (Heat Pump)
(only when heat pump is selected in #1)
10
(FA)
CR Em
SL Selects the cycle rate for Emergency
mode and Auxiliary stage if Heat Pump is
selected in item 1)
11
(OFF) CL CL On Compressor Lockout Time
12
Heat-Auto
Cool-Off
Cool-Off, Heat-Off,
Heat-Fan-Off,
Heat-Cool Auto-Off
Select System Switch Configuration with automatic
changeover capability
13
(On) dL dL OFF Selects Display Light On or OFF
14
0
(current temperature)
1 HI, 2 HI, 3 HI, 4 HI,
1 LO, 2 LO, 3 LO, 4 LO
Adjustable Ambient Temperature Display
15
°F °C
Selects Fahrenheit/Celsius Temperature Display
16
L (90) Heat L 62 to L 89 Selects Limited HEAT Range
17
L (45) Cool L 46 to L 82 Selects Limited COOL Range
18
P7 P3 Defaults for 7 day programming (P7) or 5/1/1 day
programming (P3) is available
19
(On) AS Heat OFF Automatic Schedule for heat mode.
20
(On) AS Cool OFF Automatic Schedule for cool mode.
21
MS (On) FA Heat OFF Fast Heat option may be disabled by
selecting OFF. NA to SS config.
22 HP2
(On) FA Cool OFF Fast Cool option may be disabled by
selecting OFF. NA to SS config.
NA to Heat only system.
23
(OFF) CA
On
Selects active Comfort Alert On or OFF.
Require CA II Module. (Not available on earlier models)
24
(On) dS OFF Selects Automatic daylight Savings Time
option On or OFF.
25
(OFF) Change Filter On Selects Filter Change-out Indicator On or OFF.
26
(200 h) Change Filter 25-1975 h Change Filter time in 25 hour increments. This
menu only appears if On is selected in above.
27
(o) On Cool (b) On Heat Selects operation of the reversing valve terminal (O/B)
output as an O or B terminal.