White Rodgers 1F95-0477 Thermostat User Manual


 
10
Worksheet for Re-Programming 7 Day and 5+1+1 Day Program
Cooling
Program
Wake Up
(Period 1)
Leave For Work
(Period 2)
Return Home
(Period 3)
Go To Bed
(Period 4)
MON
6:00 AM 75°F 8:00 AM 83°F 5:00 PM 75°F 10:00 PM 78°F
TUE
WED
THU
FRI
SAT
6:00 AM 75°F 8:00 AM 83°F 5:00 PM 75°F 10:00 PM 78°F
SUN
6:00 AM 75°F 8:00 AM 83°F 5:00 PM 75°F 10:00 PM 78°F
Heating
Program
Wake Up
(Period 1)
Leave For Work
(Period 2)
Return Home
(Period 3)
Go To Bed
(Period 4)
MON
6:00 AM 70°F 8:00 AM 62°F 5:00 PM 70°F 10:00 PM 62°F
TUE
WED
THU
FRI
SAT
6:00 AM 70°F 8:00 AM 62°F 5:00 PM 70°F 10:00 PM 62°F
SUN
6:00 AM 70°F 8:00 AM 62°F 5:00 PM 70°F 10:00 PM 62°F
PROGRAMMING
TROUBLESHOOTING
Comfort Alert Codes
The Comfort Alert diagnostics product monitors the air
conditioning outdoor systems with single phase Copeland
Scroll compressors. Abnormal system and electrical
conditions are indicated by flashing ALERT codes on the
yellow LED on the Comfort Alert module. The flash codes are
transmitted to the thermostat by the Comfort Alert Thermostat
interface module. The Comfort Alert compatible thermostat
displays “Call For Service” that flashes at the same rate as
the yellow LED on the Comfort Alert module.
Comfort Alert Yellow Alert Codes
1 Flash Long run time
2 Flashs System pressure trip
3 Flashs Short cycling
4 Flashs Locked rotor
5 Flashs Open circuit
6 Flashs Open start circuit
7 Flashs Open run circuit
8 Flashs Welded Contactor
9 Flashs Low voltage