This section will help you plan your thermostat's program to
meet your needs. For maximum comfort and efficiency, keep the
following guidelines in mind when planning your program.
When heating (cooling) your building, program the temper-
atures to be cooler (warmer) when the building is vacant or
during periods of low activity.
During early morning hours, the need for cooling is usually
minimal.
Planning Your ProgramPlanning Your Program
Planning Your ProgramPlanning Your Program
Planning Your Program
Look at the factory preprogrammed times and temperatures
shown in the sample schedule. If this program will suit your
needs, simply press the RUN button to begin running the factory
preset program.
If you want to change the preprogrammed times and tempera-
tures, follow these steps.
Determine the time periods and temperatures for your program.
You can program four or two periods for each day (see Configu-
ration menu, item 3). You may use the same heating and cooling
temperatures for consecutive time periods. You can choose
start times, heating temperatures, and cooling temperatures
independently (for example, you may select 5:00 AM and 70° as
the weekday
1st period heating1st period heating
1st period heating1st period heating
1st period heating start time and temperature and
also choose 7:00 AM and 76° as the weekday
1st period1st period
1st period1st period
1st period
coolingcooling
coolingcooling
cooling start time and temperature).
Use the table to plan your program time periods and the
temperatures you want during each period. Fill in the complete
table to have a record of your programs.
PERIOD 1
Time Temp Time Temp
Heating/Cooling Schedule Plan
Mon
Tues
Wed
Thur
Fri
Sat
Sun
HEAT COOL
PERIOD 2
Time Temp Time Temp
HEAT COOL
PERIOD 3
Time Temp Time Temp
HEAT COOL
PERIOD 4
Time Temp Time Temp
HEAT COOL
1ST
2ND
3RD
4TH
1ST
2ND
3RD
4TH
SAMPLE
Heating/Cooling Schedule Plan (Factory Program)
6:00 AM
8:00 AM
5:00 PM
10:00 PM
6:00 AM
8:00 AM
5:00 PM
10:00 PM
70 F
62 F
70 F
62 F
78 F
85 F
78 F
82 F
ALL DAYS OF THE WEEK
Start Time Temperature
Period
COOL HEAT
Entering Your ProgramEntering Your Program
Entering Your ProgramEntering Your Program
Entering Your Program
Set Current Time and DaySet Current Time and Day
Set Current Time and DaySet Current Time and Day
Set Current Time and Day
1. Press TIME button once. The display will show the hour
only.
EXAMPLE:
2. Press and hold either
or until you reach the
correct hour and AM/PM designation (
AM AM
AM AM
AM begins at mid-
night;
PM PM
PM PM
PM begins at noon).
3. Press TIME once again. The display window will show
the minutes only.
EXAMPLE:
4. Press and hold either
or until you reach the
correct minutes.
5. Press TIME once again. The display will show the day of
the week.
6. Press
or until you reach the current day of the
week.
7. Press RUN once. The display will show the correct time
and room temperature alternately.
PM
Enter Heating ProgramEnter Heating Program
Enter Heating ProgramEnter Heating Program
Enter Heating Program
1. Move the SYSTEM switch to HEAT.
2. Press PRGM once. MO (indicating Monday program)
will appear in the display. Also displayed are the currently
programmed start time for the 1st heating period and the
currently programmed temperature (flashing).
EXAMPLE:
This display window shows that for Mondays 1st heating
period, the start time is 6:00 AM, and 70° is the programmed
temperature (this example reflects factory preprogramming).
3. Press or to change the displayed temperature to
your selected temperature for Mondays 1st heating
program period.
4. Press TIME once (the programmed time will flash). Press
or until your selected start time for Mondays 1st