White Rodgers 1F85-277 Air Conditioner User Manual


 
6
Press the SYSTEM button until
OFF OFF
OFF OFF
OFF is displayed, then press the and simultaneously
INSTALLER/CONFIGURATION MENUINSTALLER/CONFIGURATION MENU
INSTALLER/CONFIGURATION MENUINSTALLER/CONFIGURATION MENU
INSTALLER/CONFIGURATION MENU
PressPress
PressPress
Press
DisplayedDisplayed
DisplayedDisplayed
Displayed
Press Press
Press Press
Press
or or
or or
or
StepStep
StepStep
Step
Button(s)Button(s)
Button(s)Button(s)
Button(s)
(Factory Default)(Factory Default)
(Factory Default)(Factory Default)
(Factory Default)
to selectto select
to selectto select
to select
CommentsComments
CommentsComments
Comments
1
SystemSystem
SystemSystem
System
MS 2MS 2
MS 2MS 2
MS 2
SS1, HP2, HP1SS1, HP2, HP1
SS1, HP2, HP1SS1, HP2, HP1
SS1, HP2, HP1 Selects Single stage, Multi-stage, or Heat Pump
(Single stage or 2-stage) System Configuration
2
SystemSystem
SystemSystem
System
7d7d
7d7d
7d
5d, 0d5d, 0d
5d, 0d5d, 0d
5d, 0d Selects Programs Per Week
3
SystemSystem
SystemSystem
System
PRG 4PRG 4
PRG 4PRG 4
PRG 4
PRG 2PRG 2
PRG 2PRG 2
PRG 2 Selects Programmable Periods (PRG 2 = 2
programmable periods; PRG 4 = 4 programmable periods)
4
SystemSystem
SystemSystem
System
4:00 HOLD4:00 HOLD
4:00 HOLD4:00 HOLD
4:00 HOLD
0:15 to 4:000:15 to 4:00
0:15 to 4:000:15 to 4:00
0:15 to 4:00 Selects Temporary Program Override Time
(increments of 15 minutes)
5
SystemSystem
SystemSystem
System
EMREMR
EMREMR
EMR
OFFOFF
OFFOFF
OFF Selects Energy Management Recovery
OFF OFF
OFF OFF
OFF or
ONON
ONON
ON
(ON)(ON)
(ON)(ON)
(ON)
6
SystemSystem
SystemSystem
System
FAFA
FAFA
FA
SLSL
SLSL
SL Selects Fast or Slow Cycle Selection
7
SystemSystem
SystemSystem
System
CLCL
CLCL
CL
CLCL
CLCL
CL Selects Compressor Lockout
CL OFFCL OFF
CL OFFCL OFF
CL OFF or
ONON
ONON
ON
(OFF)(OFF)
(OFF)(OFF)
(OFF)
(ON)(ON)
(ON)(ON)
(ON)
8
SystemSystem
SystemSystem
System
CDLCDL
CDLCDL
CDL
CDLCDL
CDLCDL
CDL Selects Backlight Display
(ON)(ON)
(ON)(ON)
(ON)
(OFF)(OFF)
(OFF)(OFF)
(OFF)
9
SystemSystem
SystemSystem
System
FAFA
FAFA
FA
FAFA
FAFA
FA Selects Fast Second Stage
ON ON
ON ON
ON or
OFFOFF
OFFOFF
OFF
(ON)(ON)
(ON)(ON)
(ON)
(OFF)(OFF)
(OFF)(OFF)
(OFF)
10
SystemSystem
SystemSystem
System
0 FLTR0 FLTR
0 FLTR0 FLTR
0 FLTR
50-195050-1950
50-195050-1950
50-1950 (increments of 50) Selects filter replacement run time
11
SystemSystem
SystemSystem
System
0°F0°F
0°F0°F
0°F
4 LO to 4 HI4 LO to 4 HI
4 LO to 4 HI4 LO to 4 HI
4 LO to 4 HI Selects Temperature Display Adjustment
4 LO4 LO
4 LO4 LO
4 LO to
4 HI4 HI
4 HI4 HI
4 HI
(Room Temperature)
12
SystemSystem
SystemSystem
System
°F°F
°F°F
°F
°C°C
°C°C
°C Selects temperature display
F° or
°C°C
°C°C
°C selection
13
SystemSystem
SystemSystem
System
AU OnAU On
AU OnAU On
AU On
OFFOFF
OFFOFF
OFF Selects AUTO Mode ON or OFF
14
SystemSystem
SystemSystem
System
LRLR
LRLR
LR
LR 62 to LR89LR 62 to LR89
LR 62 to LR89LR 62 to LR89
LR 62 to LR89 Selects Limited
HEAT HEAT
HEAT HEAT
HEAT range
(90)(90)
(90)(90)
(90)
15
SystemSystem
SystemSystem
System
LRLR
LRLR
LR
LR 46 to LR 82LR 46 to LR 82
LR 46 to LR 82LR 46 to LR 82
LR 46 to LR 82 Selects Limited COOL range
(45)(45)
(45)(45)
(45)
16
SystemSystem
SystemSystem
System
CACA
CACA
CA
CACA
CACA
CA Feature Not Available
(OFF)(OFF)
(OFF)(OFF)
(OFF)
(ON)(ON)
(ON)(ON)
(ON)
17
SystemSystem
SystemSystem
System
(ON)(ON)
(ON)(ON)
(ON) Selects Keypad Lockout
(OFF)(OFF)
(OFF)(OFF)
(OFF)
18
SystemSystem
SystemSystem
System
00
00
0
001 to 999001 to 999
001 to 999001 to 999
001 to 999 Selects Keypad lockout combination number
Press System to set code
19
RunRun
RunRun
Run Returns to the OFF position
CONFIGURATION MENUCONFIGURATION MENU
CONFIGURATION MENUCONFIGURATION MENU
CONFIGURATION MENU
programmable, SYSTEM button selection will skip
Programmable periods (item 3), programmable hold time
(item 4) and EMR (item 5).
3)
Programmable Periods Programmable Periods
Programmable Periods Programmable Periods
Programmable Periods – This control can be configured
for 4 or 2 programmable periods. The display indicates
“PRG 4”“PRG 4”
“PRG 4”“PRG 4”
“PRG 4” in the display as default. The programmable
periods can be toggled to
“PRG 2”“PRG 2”
“PRG 2”“PRG 2”
“PRG 2” by pressing the
or keys.
4)
Select Temporary Program Override TimeSelect Temporary Program Override Time
Select Temporary Program Override TimeSelect Temporary Program Override Time
Select Temporary Program Override Time – The thermo-
stat can hold any temperature you set it to for the amount
of time you select on this option. Your choices are 0:15 to
4:00 hours in 15 minute increments.
Example:
1. You have selected 3:00 hours for the Temporary Pro-
gram Override time period.
2. With the thermostat set to Heat or Cool, press
or
to set the temperature to your preference.
The thermostat will maintain this temperature setting for
3 hours with
“HOLD” “HOLD”
“HOLD” “HOLD”
“HOLD” blinking to remind you it is in
Temporary Hold. After 3 hours, the thermostat will go
back to the program temperature and
“HOLD” “HOLD”
“HOLD” “HOLD”
“HOLD” will no
longer blink or display.