6
• TEMPERATURE DISPLAY ADJUSTMENT — Your new
thermostat has been accurately set in our factory. However,
if you wish, you may adjust your new thermostat tempera-
ture display to match your old thermostat. This can be
accomplished (within a ±4°F range) as follows:
1. Press VIEW PRGM and HOLD TEMP buttons at the
same time.
2. Press
or to adjust the displayed temperature to
your desired setting.
3. Press RUN PRGM to resume normal program operation.
PROGRAMMING YOUR THERMOSTAT
Now you are ready to program your thermostat. This section will
help you plan your thermostat’s program to meet your needs.
For maximum comfort and efficiency, keep the following guide-
lines in mind when planning your program.
• When heating (cooling) your building, program the tem-
peratures to be cooler (warmer) when the building is vacant
or during periods of low activity.
• During early morning hours, the need for cooling is usually
minimal.
Look at the factory preprogrammed times and temperatures
shown below. If this program will suit your needs, simply press the
RUN PRGM button to begin running the factory preset program.
If you want to change the preprogrammed times and tempera-
tures, follow these steps.
Determine the time periods and heating and cooling tempera-
tures for your weekday and weekend programs. You must
program four periods for both the weekday and weekend pro-
gram. However, you may use the same heating and cooling
temperatures for consecutive time periods. You can choose
start times, heating temperatures, and cooling temperatures
independently for both weekday and weekend programs (for
example, you may select 5:00 AM and 70° as the weekday 1st
period heating start time and temperature, and also choose
7:00 AM and 76° as the weekday 1st period cooling start time
and temperature).
Use the table at the bottom of the page to plan your program time
periods, and the temperatures you want during each period. You
may also want to look at the sample program table to get an idea
of how the thermostat can be programmed.
Entering Your Program
Follow these steps to enter the heating and cooling programs
you have selected.
Set Current Time and Day
1. Press SET TIME button once. The display will show the hour
only.
EXAMPLE:
P
2. Press and hold either or until you reach the correct
hour (the letter P should be displayed for PM time, which
begins at noon).
3. Press SET TIME once. The display window will show the
minutes only.
EXAMPLE:
4. Press and hold either or until you reach the correct
minutes.
5. Press SET TIME once. The display will show the day of the
week.
6. Press or until you reach the current day of the week.
7. Press RUN PRGM once. The display will show the correct
time and room temperature alternately.
Enter Heating Program
1. If you want to change the display from Fahrenheit to Celsius
(or vice-versa), press SET TIME and HOLD TEMP at the
same time.
2. Press the SYSTEM button until HEAT is displayed.
3. Press VIEW PRGM once. “MO TU WE TH FR” (indicating
weekday program) will be displayed. Also displayed are
the currently programmed start time for the 1st heating
period and the currently programmed temperature
(flashing).
Heating Program for
ALL days of the Week:
Cooling Program for
ALL Days of the Week:
PERIOD TIME TEMP PERIOD TIME
TEMP
1st
2nd
3rd
4th
6:00 AM
8:00 AM
5:00 PM
10:00 PM
70°F
62°F
70°F
62°F
1st
2nd
3rd
4th
6:00 AM
8:00 AM
5:00 PM
10:00 PM
78°F
85°F
78°F
82°F
FACTORY PREPROGRAMMING
WEEKDAY (5 DAY)
WEEKEND (2 DAY)
Start
Time Temperature
Start
Time Temperature
1ST HEAT
2ND HEAT
3RD HEAT
4TH HEAT
1ST COOL
2ND COOL
3RD COOL
4TH COOL
Heating/Cooling Schedule Plan
Period
WEEKDAY (5 DAY)
WEEKEND (2 DAY)
Start
Time Temperature
Start
Time Temperature
1ST HEAT
2ND HEAT
3RD HEAT
4TH HEAT
1ST COOL
2ND COOL
3RD COOL
4TH COOL
SAMPLE
Heating/Cooling Schedule Plan
Period
5:30 AM
8:00 AM
5:00 PM
10:30 PM
6:30 AM
2:00 PM
5:00 PM
10:30 PM
7:00 AM
11:00 AM
6:00 PM
11:30 PM
7:00 AM
12:30 PM
6:00 PM
11:30 PM
68°F
70°F
70°F
65°F
76°F
74°F
72°F
78°F
68°F
65°F
70°F
65°F
76°F
78°F
72°F
78°F