Whirlpool ACE184XR0 Air Conditioner User Manual


 
11
Position ground wire pointing straight up. Put excess ground
wire between coil and air conditioner cabinet.
6. Push front panel straight on and then lower it slightly to lock it
into place.
7. Using the indents in top of filter door, pull door down.
8. Using 2 - #8 - 18 x ³⁄₈" round-head screws, attach bottom
front of panel.
NOTE: For through-the-wall installations, if needed, install
molding around room side of cabinet.
9. Plug into a grounded 3 prong outlet.
10. Press RESET on the power supply cord.
AIR CONDITIONER USE
Operating your air conditioner properly helps you to obtain the
best possible results.
This section explains proper air conditioner operation.
IMPORTANT:
If you turn the air conditioner off, wait at least 3 minutes
before turning it back on. This prevents the air conditioner
from blowing a fuse or tripping a circuit breaker.
Do not try to operate your air conditioner in the cooling mode
when outside temperature is below 65°F (18°C). The inside
evaporator coil will freeze up, and the air conditioner will not
operate properly.
NOTE: In the event of a power failure, your air conditioner will
operate at the previous settings when the power is restored.
Starting Your Air Conditioner—
Digital Control
A.Green ground wire
B.Ground screw
A. Indents
A
B
A
A.Front of unit
B.2 - #8 - 18 x
³⁄₈
" round-head screws
A
B
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING