Whirlpool ACM184XE0 Air Conditioner User Manual


 
Receptacle wiring
See the chart below for minimum gauge for
receptacle wiring. Use copper wire only. It is
the responsibility of the consumer to provide
proper and adequate receptacle wiring,
installed by a qualified electrician. Observe
the National Electrical Code and all local
governing codes and ordinances.
REQUIREMENTS
l 115 volt (103.5 min.-
126.5 max.)
l O-l 2 amperes
l 15 amp time-delay fuse or
circuit breaker
COPPER WIRE
14 gauge
PLUG
‘.I
Bl
!’
l 230 volt (207 min.-253 max.)
or
14 gauge
l 230/208 volt (197.6 min.-
253 max.)
l O-l 2 amperes
l 15 amp time-delay fuse or
circuit breaker
l 230 volt (207 min.-253 max.)
or
12 gauge
l 230/208 volt (197.6 min.-
253 max.)
l O-l 6 amperes
l 20 amp time-delay fuse or
circuit breaker
l 230 volt (207 min.-253 max.)
or
10 gauge
l 230/208 volt (197.6 min.-
253 max.)
l O-24 amperes
l 30 amp time-delay fuse or
circuit breaker
5