Whirlpool 1187361 Air Conditioner User Manual


 
10
Complete Installation
1. Place window-lock bracket on top of lower window and
against upper window sash.
2. Use a ³⁄₃₂ in. drill bit to drill a starter hole through the hole in
the bracket into the window sash.
3. Attach window-lock bracket to window sash with #8 x ³⁄₄ in.
round-head screw to secure window in place.
4. Insert foam seal behind the top of the lower window sash and
against the glass of the upper window.
5. Plug into a grounded 3 prong outlet.
AIR CONDITIONER USE
Operating your air conditioner properly helps you to obtain the
best possible results.
This section explains proper air conditioner operation.
IMPORTANT:
If you turn off the air conditioner, wait at least 3 minutes
before turning it back on. This prevents the air conditioner
from blowing a fuse or tripping a circuit breaker.
Do not try to operate your air conditioner in the cooling mode
when outside temperature is below 65°F (18°C). The inside
evaporator coil will freeze up, and the air conditioner will not
operate properly.
NOTE: In the event of a power failure, your air conditioner will
operate at the previous settings when the power is restored.
Starting Your Air Conditioner -
Digital Control
1. Remove clear protective film from control panel and front
panel badge.
2. Press POWER to turn on air conditioner.
NOTE: When air conditioner is turned on for the first time
after it is plugged in, it will display the default settings: Cool
mode, Turbo fan speed, 72°F (22°C). When it is turned on at
all other times, it will display the previous settings.
3. Select mode. See Mode.
4. Select fan speed. See Fan Speed.
5. Set temperature. See Temperature.
1. Upper window sash
2. Window-lock bracket
1. Lower window sash
2. Foam seal
1
2
1
2
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Do not use an extension cord.
Do not use an adapter.
Do not remove ground prong.