Waterford Appliances E61-NG Indoor Fireplace User Manual


 
5Waterford E61 Gas Fireplace Insert
This is a copy of the label that accompanies
each Waterford E61-LP Gas Insert Propane.
We have printed a copy of the contents here for
your review. The safety label is located on the
right side door panel.
NOTE: Waterford units are constantly being
improved. Check the label on the unit and if there
is a difference, the label on the unit is the correct
one.
SAFETY LABEL
DUPLICATE SERIAL NO.
DO NOT REMOVE OR COVER THIS LABEL /
NE PAS ENLEVER CETTE TIQUETTEÉ
204
204
Serial no./
No de serie
908-438b
12" WC/C.E. (3.00 kPa)
11" WC/C.E. (2.74 kPa)
2.9" WC/C.E. (0.72 kPa)
Minimum supply pressure
Manifold pressure High
Manifold pressure Low
Factory Equipped for 35,000 Btu
Maximum Input
Minimum Input
Orifice size
Altitude
Convertible to 29,000 Btu for Altitude 0 - 4500 ft. with Kit #: 260-922
Maximum Input
Minimum Input
Orifice size
Altitude
FACTORY EQUIPPED FOR PROPANE Model:E61LP
Pression d'allimentation minimum
Pression la tubulure d' chappement lev e
Pression la tubulure d' chappement basse
à
à
ééé
é
35,000 Btu/h (10.26 Kw/h)
17,500 Btu/h (5.13 Kw/h)
#50 DMS (1.8mm)
0-2000 ft/pi (0-610m)
D bit Calorifique maximum
D bit Calorifique minimum
Dimensions de l'orifice
L'altitude
é
é
D bit Calorifique maximum
D bit Calorifique minimum
Dimensions de l'orifice
L'altitude
é
é
ÉÉQUIP A L'UISINE POUR GAZ PROPANE
29,000 Btu/h (8.50 Kw/h)
14,500 Btu/h (4.25 Kw/h)
#52 DMS (1.61mm)
0-4500 ft/pi (0-1372m)
Listed:
Report No.
VENT GAS FIREPLACE HEATER
476-1714-00 (Oct. 1999)
Certified for/Certifi e pour: CANADA and U.S.A.é
ANSI Z21.88b-2003/CSA 2.33b-2003, /CGA 2.17-M91Tested to: CAN
FPI Fireplace Products International Ltd., Delta, BC, Canada
Made in Canada/ Fabrique au Canada
This appliance must be installed in accordance with
local codes, if any; if none, follow the National Fuel
Gas Code, ANSI Z223.1/NFPA54, or Natural Gas and
Propane Installation Codes, CSA B149.1.
FOR USE WITH GLASS DOORS CERTIFIED WITH
APPLIANCE ONLY.
This vented gas fireplace heater is not for
use with air filters.
Not for use with solid fuel.
Electrical Supply (115 V, 1.13A, 60 Hz)
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an
aftermarket, permanenlty located,manufactured (mobile) home where not prohibited by local codes. See owner's
manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used.
A
B
Minimum Clearances
to Combustibles/
Degagement Minimum
De Materiaux Combustibles
Unit to Sidewalls A 9"/230mm
Top of Hob to mantel:
unshielded B 16"/406mm
shielded B 12"/305mm
To ceiling fromtop of stove: 36"/ 915mm
Approved for use with Emerald Zero Clearance Kit, Part No. 270-900.
Floor Protector
Afloor protector consisting of one layer of ½" thick
WonderBoard , Durock ,or equivalent extending
at least 9" in front of the face of the unit and the full
width of the front surface is required.