9Waterford E61 Gas Fireplace Insert
CONVERSION KIT
FROM NATURAL GAS
TO PROPANE MODEL
#260-960
for Emerald E61 Gas Insert
using SIT 820 NOVA Gas Valve
THIS CONVERSION MUST BE
DONE BY A QUALIFIED
GAS FITTER
IF IN DOUBT DO NOT DO THIS
CONVERSION !!
Conversion Kit Contains:
Qty.Part # Description
1 910-018 SIT Conversion Kit-50%
Turndown LP
1 910-383 LP Injector (Pilot Orifice)
1 904-641 Burner Orifice #50
1 908-455 Decal "Converted to Propane"
1 908-528 Red "PROPANE" label
1 908-173 Instruction Sheet
1) Shut off the gas supply.
2) Open the lower grill and remove the 2
screws holding the control panel in place.
Remove the 2 screws holding the
Control Panel in place.
FLUE LINER
INSTALLATION
1) Cut the flex liner as required.
2) Mark the end of one liner to indicate
Inlet.
3) Connect the other end of the above liner to
the inlet side of the termination adaptor, seal
connection with high temperature silicone.
Secure with gear clamp.
4) Connect the 2nd liner to the exhaust side of
the adaptor, seal connection with high tem-
perature silicone. Secure with gear clamp.
5) Install flashing.
6) Insert both liners into chimney, passing
through the damper opening.
7) Install termination cap.
8) Connect the marked end of the liner to
the inlet collar of the vent connector plate
marked with an "I", seal connection with
high temperature silicone. Secure with
gear clamp.
9) Connect the 2nd liner to the exhaust collar
marked with an "E", seal connection with
high temperature silicone. Secure with
gear clamp.
Part # Description
948-305 3" Flex - 35 ft.
946-529 Co-linear DV Vertical
Termination Cap
Alternate Approved Caps
980 Vertical Termination Cap
991 High Wind Cap
923GK 3" Co-linear Adaptor with flashing
In areas on consistently high winds, we recom-
mend using the Simpson Dura-Vent System
(923GK adapter and 991 high-wind cap).
The Air Intake pipe must be attached to the inlet
air collar of the termination cap.
INSTALLATION
NOTE:
1) Final gas connection should be made
after unit is in place to avoid damage to
line when pushing the unit into position.
2) Mill-pac may be used instead of high
temperature silicone and screws may
be used instead of gear clamps at con-
nections of liner to inlet and vent col-
lars.
10)Attach the top shield to the top front lip of
the firebox using 3 screws.