Vanguard VE32LBH Indoor Fireplace User Manual


 
www.desatech.com
115121-01B18
SERVICING FAN BLOWER
To remove fan blower:
1. Follow instructions under Accessing Imag-
ing Unit, page 17.
2. Remove 3 light bulbs from lamp xtures
(see Replacing Light Bulbs, page 15).
3. Disconnect two 1/4" blade connectors
from posts on motor unit.
4. Remove 4 hex nuts and washers located
on blower mounts at base of cabinet (see
Figure 37).
5. Lift entire fan assembly off of mounts and
tilt out of unit.
6. Remove screws with washers and hex
nuts from fan housing.
7. Mount new fan to blower mount in reverse
order.
8. Slide blower assembly with spacers over
mounting lugs and replace washer and
nut at each lug. Do not over tighten.
9. Attach blade connectors to posts on
motor mount. Note: Wire connectors for
fan motor are non-polarized and may be
connected to either terminal for proper
operation.
SERVICING FLAME PENNANTS
If ame pennants should become tangled or
detached reattach or replace.
1. Locate affected ame pennant. Slip hem
at base of ame pennant over proper
hanger bracket position. See Figure 38,
page 19, for proper location.
2. Pull ame cord up to proper hook location,
use a slip knot to adjust cord length and
attach cord to hook.
3. Tie another knot over slip knot and trim
away excess cord.
MAINTENANCE
Continued
Figure 36 - Removing Base Cover
Base
Cover
Figure 37 - Removing Fan Assembly (Shown without Firebox for Clarity)
Washer
Hex Nut
Fan Assembly
Blower
Mount
(1 of 4)
Washer
Hex
Nut
Screw
Spacer
Posts for Blade
Connectors