Vanguard VE32LBH Indoor Fireplace User Manual


 
www.desatech.com
115121-01B 13
TROUBLESHOOTINg
Note: Before troubleshooting system, make sure power to circuit from breaker or fuse panel
is turned ON.
The three most common causes of a malfunctioning electric replace are:
1. Tripped circuit breaker or blown fuse.
2. Loose or burned out light bulb.
3. Obstructed or clogged fan blower.
POSSIBLE CAUSE
1. No power to replace
2. Defective switch lamp
3. Defective wiring
1. Tangled or loose flame
pennants
2. Obstructed or clogged fan
blower
3. Damaged or dislodged fan
blower wheel
1. Burned out or loose light
bulb
2. Broken lamp xture
3. Loose or missing reective
ribbons
1. Obstructed heater blower
2. Burned out heat element
or blower fan
3. Defective heater switch or
wiring
REMEDY
1.
Check circuit breaker or fuse
2. Replace defective switch.
See Servicing Control Pan-
el, page 16
3. Check connections from
main power harnesses to
terminals on control panel.
See Servicing Control Pan-
el, page 16
1. Inspect ame pennants. Un-
tangle or replace if neces-
sary. See Servicing Flame
Pennants, page 18
2. Check fan blower for de-
bris. Vacuum areas around
blower wheel and remove
any obstructions. See Main-
taining Motors, page 15
3. Remove and inspect fan
blower housing See Servic-
ing Fan Blower, page 18
1. Inspect light bulbs; tighten
or replace light bulbs as
necessary. See Replacing
Light Bulbs, page 15
2. Remove and replace broken
lamp xture. See Replacing
Lamp Fixtures, page 20
3. Inspect reective ribbons.
Reattach or replace as nec-
essary. See Replacing Re-
ective Ribbons, page 21
1.
Clear heater fan of debris
or blockage; vacuum area
around blower intake and
remove any obstructions
in the discharge area. See
Maintaining Motors, page 15
2. Remov and replace blower
heater assembly. To access
and remove see Optional
Heater Accessory, page
10
3. Inspect wiring connections
from switch to blower. Re-
place switch if defective.
See Servicing Control Pan-
el, page 16
OBSERVED PROBLEM
No operation or indicator light
at power/heater switch
Poor ame motion; ame pat-
tern is sporadic or uneven in
viewing area
Dull ame appearance or inac-
tive ember bed effect
No heat or intermittent heat
output. (If equipped with a
heater)