Vanguard VE32LB Indoor Fireplace User Manual


 
www.desatech.com
115121-01B 17
ACCESSING IMAGING UNIT
The imaging unit can be accessed from inside
replace for servicing as follows:
1. Remove glass doors (if equipped). See
Optional Glass Doors, on page 8.
2. Remove screens, grate, hearth pan brack-
ets and brick liners. See Figure 33 and
instructions under Optional Brick Liners,
page 9.
3. Remove 4 Phillips screws holding hearth
pan to replace and 2 screws located at
lower frame rail (see Figure 34).
4. Lift rear ends of hearth pan up until front
edge clears lower frame rail then slide
up on end and angle out of replace
opening.
5. Remove 4 Phillips screws holding face
extensions at top refractory clips (see
Figure 34).
6. Remove viewing screen from cabinet
face. Viewing screen is attached by mag-
nets (see Figure 35).
Note: Do not scratch viewing screen. Place
on a nonabrasive surface away from work
area. When replacing viewing screen painted
side must face inside of cabinet with pattern
facing up.
MAINTENANCE
Continued
Figure 33 - Accessing Imaging Unit
Refractory
Brackets
Grate
Hearth Pan
Bracket
Hearth Pan
Bracket
Brick Liner
Brick
Liner
Figure 34 - Removing Hearth Pan and
Face Extensions (VE32 Series Only)
Hearth Pan
Face Extensions
Refractory Clip
Viewing Screen
Figure 35 - Removing Viewing Screen
7. Remove 4 Phillips screws on base cover
and lift cover off cabinet base. See Figure
36, page 18.
Note: Only VE32 series models have Face
Extensions that require removal to access
Imaging Unit. Model VE36 series has inner
Face Panels that also require removal to ac-
cess Imaging Unit.