Universal SPC-30R/30R Electric Heater User Manual


 
Models
SPC-15R/15R SPC-30R/30R
Page -3-
OPERATING PRECAUTIONS
This is a propane, direct-fired, infrared heater. It's intended use
is primarily temporary heating of buildings under construction,
alteration or repair.
Propane is heavier than air. If propane leaks from a connection
or fitting, it sinks to the floor, collecting there with the
surrounding air, forming a potentially explosive mixture.
Obviously, propane leaks should be avoided, so set up the
propane supply with utmost care. Read enclosed Odor Fade
and Propane Sheet for additional information about detecting
propane leaks. Leak check new connections or reconnections
with a soap and water solution and follow all connection
instructions herein. Also, ask your propane dealer for advice on
the propane application and supply installation and ask him to
check it if there are any questions.
Check with your local fire safety authority if you have any
questions about your applications. Standards govern the use of
fuel gases and heat producting products in specific
applications. Your local authority can advise you about these.
Direct-Fired means that all of the combustion products enter the
heated space. Even though this heater operates very close to
100 percent combustion efficiency, it still produces small
amounts of carbon monoxide. Carbon monoxide (called CO) is
toxic. We can tolerate small amounts but not a lot. CO can build
up in a heated space and failure to provide adequate ventilation
could result in death. The symptoms of inadequate ventilation
are:
headache dizziness
burning eyes and nose nausea
dry mouth or sore throat
So, be sure to follow advice about ventilation in these operating
instructions.
When the heater is to be operated in the presence of other
people the user is responsible for properly acquainting those
present with the safety precautions and instructions, and of
the hazards involved.
8.Do not use heater in basement or below ground level.
9.Before connecting heater to the propane tank, make sure
the heater regulator knob is in the "OFF" position. Always
connect and light heater in areas free of open flames.
10. Mount the propane cylinders vertically (shutoff valve up).
Secure them from falling or being knocked over and protect
them from damage.
11. IMPORTANT Use only the hose and regulator assembly
provided with the model SPC-30R / 30R. Inspect the hose
assembly before each use of the SPC-30R/30R. If there is
excessive abrasion or wear, or hose is cut, replace with
hose assembly listed on parts list before using heater. The
hose and regulator must be protected from damage.
12. The heater burner must be at least 2 ft. (.61m) above the
floor. Always attach to propane tank in an upright position.
Never operate a heater on its side or attach to propane tank
in a horizontal position. This could lead to dangerous flare-
ups or fire. Do not direct heat toward propane cylinders.
13. Maintain minimum clearance from normal cumbustible
materials (like paper) as follows: Sides - 3 ft. (.91m); Top &
Front - 5 ft. (1.5m). Locate 10 ft. (3m) from canvas or plastic
tarpaulins or similar coverings and secure them to prevent
flapping or movement due to wind action.
14.If at any time gas odor is detected, IMMEDIATELY
DISCONTINUE operation until the source of gas has been
located and corrected. Read enclosed Odor fade and
Propane Sheet for additional information about detecting
propane leaks.
15.Install the heater such that is is not directly exposed to water
spray, rain, dripping water and/or wind.
16. Operate only on a stable, level surface.
17. Due to the high surface and exhaust temperatures, adults
and children must observe clearances to avoid burns or
clothing ignition.
18. Since permanent skin tissue damage can occur, do not
move, handle or service while hot or burning. Do not attach
or remove a hot or operating heater from the propane tank.
19.Before each use, check heater for leaks. Never use an
open flame to check for leaks. Apply a mixture of liquid
soap and water to all joints. Bubbles forming show a leak.
Correct all leaks.
20.Keep all connections and fittings clean. Make sure propane
tank valve is clean. Check "O" ring on heater inlet fuel valve
connector for damage before each use. Replace if worn or
damaged.
21. Use only in accordance with local codes or, in the absence
of local codes, with the Standard for the Storage and
Handling of Liquefied Petroleum Gases ANSI/NFPA 58 and
CSA B149.1, Natural Gas and Propane Installation Code.
SAFETY PRECAUTIONS
1.Keep children and animals away from heater.
2.Never operate heater while sleeping or unattended.
3.Check the heater thoroughly for damage. DO NOT operate
a damaged heater.
4.DO NOT modify the heater or operate a heater which has
been modified from its original condition.
5.Use only propane gas.
6.Use only VAPOR WITHDRAWAL propane supply. If there is
any question about vapor withdrawal, ask your propane
dealer.
7.For outdoor use only. AREA MUST BE WELL VENTILATED.
Provide minimum openings of 1 sq ft (.093m²) near the
floor and 1 sq ft. (.093²) near the ceiling. Do not use inside
house, camper, tent and vehicle. Or any type of unvented or
enclosed area.