United States Stove C9947N Stove User Manual


 
9947 SPECIFICATIONS
Natural Gas
Manifold Pressure Setting: 4" w.c.
Gas Inlet Pressure: Maximum 10-1/2" w.c.
Minimum 5" w.c.
Propane/LPG
Manifold Pressure Setting: 10" w.c.
Gas Inlet Pressure: Maximum 13" w.c.
Minimum 11" w.c.
5
CAUTION
GLOVES ARE RECOMMENDED WHEN HANDLING CERAMIC FIBER
LOGS TO PREVENT SKIN IRRITATION FROM LOOSE FIBERS. LOGS
ARE FRAGILE, HANDLE WITH CARE.
Carefully inspect the contents for shipping damage and immediately inform
your dealer if any damage is found.
9947L and 9947N Unvented Gas Heaters
1. Packet containing Homeowner's/Installation instructions.
2. Three (3) individually wrapped fiber ceramic logs, refer to installation instructions.
3. Unvented gas heater.
CHECK THAT ALL LISTED PARTS HAVE BEEN RECEIVED
CONTENTS
Gas Rate Number
Model Number Type Max BTU/Hr Min BTU/Hr of Burners
9947N Manual 39,900 27,000 1
9947L Manual 39,900 27,000 1
Controls - Main control has 4 positions:
1. OFF - All gas to the gas logs is shut off at the control
2. IGN - Piezo ignitor allows ignition of the pilot without the use of matches or batteries
3. PILOT - Valve position to light/maintain a standing pilot
4. ON - Gas flow to complete system.
HIGH / LOW Control - Infinite control :
Rotate knob clockwise to LOW, counter clockwise to HIGH.