United States Stove 58242 Stove User Manual


 
6 USSC
Installation
CLEARANCES
YourForesterstovehasbeentestedandlistedforinstallationinresidential,mobilehome,andalcoveapplicationsin
accordancewiththeclearancesgiveninFIGURES3-4andTABLE1.
NOTE: Distance “D” on the left-hand side of your Forester stove may need to be greater than the minimum
required clearance for suitable access to the control panel.
FIGURE 3
SIDEWALL/CORNER
MINIMUMCLEARANCES
FIGURE 4
MINIMUMALCOVECLEARANCES
PARALLEL A-Backwalltoheater 8.00”/203mm
B-Backwalltoue 1.00”/25mm
C-Sidewalltoue 7.50”/191mm
D-Sidewalltoedgeofunit 4.00”/100mm
CORNER E-Adjacentwalltounit 2.00”/50mm
ALCOVE F-Alcovedepth 25.00”/635mm
G-AlcoveHieght 47.00”/1194mm
AlcoveWidth 26.50”/673mm
TABLE 1
MINIMUMCLEARANCES
(inches/mm)