12 USSC
Control Panel Overview
ON/OFF
Pressingthe“ON”buttononthecontrolpanelwillbeginthestart-upsequencefortheheater.Fuelwillbegintofeed
throughtheaugerfeedsystemthenigniteafterapprox.5minutes.
Pressingthe“OFF”buttononthecontrolpanelwillcausetheheatertoenteritsshut-downsequence.Thefuel
feedsystemwillstoppullingfuelfromthehopperand,oncetheregoesoutandtheheatercoolsdown,thefans
willstoprunning.
HEAT RANGE
Pressingthe“HeatRange”arrows,upordown,willadjusttheamountoffuelbeingdeliveredtotheburnpot.
DRAFT FAN
Thedraftfan(exhaust)willcomeonassoonasthe“ON”buttonispressed.Thefanwillautomaticallyadjustits
speedinaccordance
totheheatrangesetting.However,thisspeedcanbemanually
operatedbypressingthe
“DraftFan”arrowsupordown.“DraftFan”whenpressed,thedisplaywillshow“Df-A”,whichisautomatic.Press
thearrowsagaintoadjustfanspeed.Whentheheaterisinthemanualmode,theoptionalthermostatwillnot
properlycontroltheunit.WhenadjustingtheDraftFansetting,tryonly1settingaboveorbelowtheheatsetting.It
isbettertoleavethestoveintheautomaticmode.
ROOM FAN
Theroomfanwillcomeononcetheunithasreachedoperatingtemperature.Bypressingthe“RoomFan”buttons,
thedisplaywillshow“Rf-A”whichisautomaticor“Rf-1”through“Rf-9”formanualsettings.Inautomode,theroom
fan’sspeedwillautomaticallybeadjustedinaccordancewiththeheatrangesetting.Bypressingthe“RoomFan”
uparrow,youcanadjustthefanspeedsettingupto“Rf-9”.Theroomfanmustoperateatalevelgreaterthanor
equaltotheheatrangesetting.
AUX-USEDTORETURNTHESTOVETOTHEFACTORYSETTINGS
Toreturnthestovetoit’soriginalfactorysettings,pressandholdtheAUXUPandAUXDOWNbuttonssimultaneously
for3seconds.
AUGER DELAY
The“AugerDelay”buttoncanbeusedtopauserotationoftheAugerforapprox.1minute.Thiscanbecancelledby
pressingthe“ON”button.The“AugerDelay”isnormallyusedonlyduringthestartupcycletoslowthefueldelivery
downduringtheinitialignition.
MODE
The“Mode”buttonisusedtoswitchbetweenmanualandautomaticmode.Wheninautomode,thefansandauger
willoperateatpresetintervalsunlesschangedmanuallyusingthebuttonsmentionedabove.Wheninmanualmode,
thedraftfan(exhaust)willoperateatfullspeed(100%).
Duringnormaloperation,theunitisconstantlymonitoredforproblems.Intheeventofanerrorcondition,theunit
willstopandanerrorwillbedisplayed.Seethelistoferrorcodesfoundattheendofthismanual.
TurningtheheaterON/OFF,aswellasadjustmentsforthefuelfeedrateandroomfanspeedareperformedbypressing
theappropriatebutton(s)onthecontrolpanelwhichislocatedonthelowerleft-handsideofyourheater.
Thisunitcanbechangedbetweenanautomaticoperationoramanualoperation.Thecontrollercomesdefaultinthe
automaticmode.