Installation
OUTSIDE AIR SUPPLY (optional)
Dependingonyourlocationandhomeconstruction,outsideairmaybenecessaryforoptimalperformance.
Metalpipe(solidorexible)mustbeusedfortheoutsideairinstallation.PVCpipeisNOTapprovedandshouldNEVER
beused.
Awindshieldovertheterminationoftheoutsideairpipeora90-degreeelboworbendawayfromtheprevailingwinds
MUSTbeusedwhenanoutsideairpipeisinstalledthroughthesideofabuilding.TheoutsideairterminationMUST
beatleast1-footawayfromtheexhaustsystemtermination.
TheoutsideairpipeonyourKing stoveis17/8”OD.Theoutsideairconnectingpipemustbeatleast17/8”ID.The
outsideairconnectionusedMUSTNOTrestricttheamountofairavailabletoyourstove.Theoutsideairconnectingpipe
mustbeasshortandfreeofbendsaspossible,anditmusttover,notinside,theoutsideairconnectiontothestove.
NOTE: Dimensionsfromthe oor toyour stoves
inlet/exhaustpipesareapproximate and may vary
dependingonyourinstallation.
FIGURE 9
TYPICALFRESHAIRTERMINATION
FIGURE 8
EXHAUST/INLETLOCATIONS
SPECIAL MOBILE HOME REQUIREMENTS


MUST BE MAINTAINED.
In addition tothepreviously detailed installation requirements, mobile home installationsmust meetthe following
requirements:
Thestovemustbepermanentlyattachedtotheoor.
Thestovemustbeelectricallygroundedtothesteelchassisofthemobilehomewith8GAcopperwireusinga
serratedorstarwashertopenetratepaintorprotectivecoatingtoensuregrounding.
Ventmustbe3or4-inch“PL”Ventandmustextendaminimumor36-inchesabovetherooflineofthemobilehome
andmustbeinstalledusingaUL/ULClistedceilingrestopandraincap.
Whenmovingyourmobilehome,allexteriorventingmustberemovedwhilethemobilehomeisbeingrelocated.
Afterrelocation,allventingmustbereinstalledandsecurelyfastened.
OutsideAirismandatoryformobilehomeinstallation.Seeyourdealerforpurchasing.
Checkwithyourlocalbuildingofcialsasothercodesmayapply.