Ultimate Products SGX Electric Heater User Manual


 
2319 Laurelbrook Street, Raleigh, NC 27604 · (800) 542-7221 · FAX (919) 834-4526 · www.ultimate-products.com
-
2
-
WARNING: Improper installation,
adjustment, alteration, service or
maintenance can cause property
damager, injury, or death. Read the
installation, operating, and maintenance
instructions thoroughly before installing or
servicing this equipment.
A. INSTALLATION INSTRUCTIONS
A.1 TECHNICAL DATA
(a) General Information
Model & Heat Input
Information all units:
Gas Supply Connection:
½-inch NPT Male
Electrical Supply:
120V, 1 phase, 60Hz
Current Rating:
1.2 AMP MAX (Burner-0.3/Fan
0.9)
Ignition:
Electronic Program Start-up with
Spark Ignition
OPTIONS:
1. Modify combustion chamber air intake for fresh air duct.
2. Ultimate Products Black Bulb Thermostat.
3. Control Panel with multi-zone capabilities. (Not A.G.A. Certified)
4. Individual Heater Vent to Exterior.
Notes:
A. Heater is intended for heating non-residential indoor and outdoor spaces and
should only be installed where flammable gases or vapors are not generally
present.
B. Indoor heaters may be suspended either horizontal or at an angle, or may be wall
mounted. Outdoor heaters must be suspended horizontally. SEE SECTION A.3
FOR CLEARANCES.
C. Installation shall conform with local building code requirements and with National
Fuel code ANSI-Z223.1.A. (Latest Edition) and section 7.8A-3; Z223.1 (Latest
Edition).
D. The unit shall be electrically grounded in accordance with National Electric Code
ANSI/NFPA 70-1987.
E. The heater may be installed in aircraft hangars when conformation with
ANSI/NFPA 409-1985 for Aircraft Hangars and in automotive garages when
conforming with ANSI-NFPA 88A (Latest Edition) for Parking Structures and
ANSI/NFPA 88B (Latest Edition) for Repair Garages.
Insure that minimum clearance will be maintained to vehicles parked below
the heater.