SYST
RPS
STAT
DUPLX
SPEED
MODE
1
5
X
3
1
X
3
3
X
4
7
X
5
0
MASTR
STACK
SYST
RPS
STAT
DUPLX
SPEED
MODE
1
5
X
3
1
X
3
3
X
MASTR
STACK
SYST
RPS
STAT
DUPLX
SPEED
MODE
1
5
X
3
1
X
3
3
X
MASTR
STACK
SYST
RPS
STAT
DUPLX
SPEED
MODE
1
5
X
3
1
X
3
3
X
MASTR
STACK
SYST
RPS
STAT
DUPLX
SPEED
MODE
1
5
X
3
1
X
3
3
X
MASTR
STACK
SYST
RPS
STAT
DUPLX
SPEED
MODE
1
5
X
3
1
X
3
3
X
MASTR
STACK
4
7
X
5
0
4
7
X
5
0
4
7
X
5
0
4
7
X
5
0
4
7
X
5
0
2
Introduction
The self-contained Portable Air Conditioning Unit provides 12,000 BTU (up to 3.4 kW) of supplemental cooling capacity. Designed for IT
environments, it’s ideal for cooling overheated rack enclosures, IT equipment hot spots and network closets without access to facility air
conditioning. The Portable Air Conditioning Unit can focus cool air through its flexible cooling duct or cool a small room through its louvered vent.
It also filters and dehumidifies air to improve operating conditions and equipment reliability. Condensate is re-evaporated for drip-free operation,
so you won’t waste time emptying water collection tanks. The self-contained design does not require any plumbing or special circuits, so setup is
quick and easy. Eco-friendly R410A refrigerant meets environmental standards worldwide.
Recommended Applications:
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the installation, operation
and storage of this product. Failure to heed these warnings may affect your warranty.
Warnings
•Theindividualusershoulddeterminepriortousewhetherthisdeviceissuitable,adequateorsafefortheuseintended.Sinceindividual
applications are subject to great variation, the manufacturer makes no representation or warranty as to the suitability or fitness of this device
for any specific application.
•Installtheunitindoors,awayfromextremetemperaturesorhumidity,directsunlight,dustandconductivecontaminants.
•Leaveadequatespacearoundtheunitforventilation,withrearandventedsidesnotlessthan20inches(51cm)fromwallsorother
obstacles.
•Installtheunitonaatsurfacewithagradientnomorethan10°.
•ConnecttheunitdirectlytoagroundedACpoweroutlet.Failuretodosomaycauseanelectricshockorre.
•Thepowersupplyfortheunitmustberatedinaccordancewiththeunit’snameplate.
•Donotmodifytheplugnoruseanadapterthatwouldeliminatethegroundconnection.
•DonotuseanextensioncordtoconnecttheunittoanACoutlet.Useonlythepowercordthatcamewiththeunit.
•Complywithallapplicablewiringandsafetyregulations,suchasNationalElectricalCode(NEC)intheUnitedStates.
•Donotplugadditionalequipmentintotheoutletwheretheunitispluggedin.Overloadingtheoutletmaycauseanelectricshockorre.
•DonotattempttoturntheunitonoroffbyconnectingordisconnectingtheACplug.Aseriouselectricshockmayoccur.UsetheON/OFF
button to turn the unit on or off.
•TurntheunitoffandunplugitfromtheACoutletbeforeperformingmaintenance.
•Beforeconnectingtheunittoadedicateddrainagesystem,turnitoffandunplugit.Thereisariskofelectricshockwhiletheunitispluggedin.
•Maintenanceshouldbeperformedbytrainedpersonnelonly.
•Donotusethinners,alcohol,detergentsorabrasivebrushestocleantheunit’scabinet.Theseitemsmaydamagethecabinet.
•Donotpourwaterovertheunit.Thismaycauseanelectricshockanddamagetheunit.
•Donotoperatetheunitwithouttheairlter.Thismaycausedustaccumulationthatmaydamagetheunit.
•Donotattempttooperatetheunitinaroomwithinadequateaircirculation.Providemakeupairinaccordancewithapplicablebuildingcodes.
•Donotplaceobjectsontopoftheunit.
•Useofthisequipmentinlifesupportapplicationswherefailureofthisequipmentcanreasonablybeexpectedtocausethefailureofthelife
support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the presence of a
flammable anesthetic mixture with air, oxygen or nitrous oxide.
1. Cooling an overheated rack enclosure. 2. Cooling an equipment hot spot inside or
outside a rack enclosure.
3. Cooling a small room.