Trion SE800E Air Cleaner User Manual


 
6
Hard wired remote control
Two sets of wiring are required to connect
the unit. Main power to the unit is 120V,
60Hz, 1Ph, rated 5 Amp - Live, Neutral and
Ground. A 5-conductor 5 Amp rated cable is
required from the unit to remote control.
Run the 5-conductor cable and the main
power connection through the cable entry
knockouts (see Fig. 5) in the cabinet and
connect to the input terminal block (Fig. 6) as
shown in the wiring diagram on page 10 and
11. Mount the remote control in the desired
position and connect the 5-conductor cable
leads to the numbered terminals as shown in
the wiring diagram.
OPTIONAL INFRARED CONTROL
Main power to the unit is 120V, 60Hz,
1Ph,
rated 5 Amp - Live, Neutral and
Ground. To
install, follow the instructions included with
the infrared control kit.