Troubleshooting
If the media converter fails, isolate and correct the failure by determining the
answers to the following questions and then taking the indicated action:
1. Is the PWR LED illuminated?
NO
Is the media converter slide-in-module installed properly in the
chassis?
Is the power cord properly installed in the chassis and at the external
power source?
Does the external power source provide power?
Contact Tech Support: (800) 260-1312, Int’l: 00-1-952-941-7600.
YES
Proceed to step 2.
2. Is the LKC LED illuminated?
NO
Check twisted-pair cables for proper connection.
Contact Tech Support: (800) 260-1312, Int’l: 00-1-952-941-7600.
YES
Proceed to step 3.
3. Is the LKF LED illuminated?
NO
Check fiber cables for proper connection.
Verify that TX and RX cables on media converter are connected to
RX and TX ports, respectively, on other device.
Contact Tech Support: (800) 260-1312, Int’l: 00-1-952-941-7600.
YES
Proceed to step 4.
4. Is the RXC LED flashing?
NO
If there is no activity on the 10Base-T port, proceed to step 5.
If there is activity on the 10Base-T port, disconnect and reconnect the
10Base-T cable to restart the initialization process.
Restart the workstation to restart the initialization process.
Contact Tech Support: (800) 260-1312, Int’l: 00-1-952-941-7600.
YES
Proceed to step 5.
5. Is the RXF LED flashing?
NO
If there is no activity on the 10Base-FL port, continue below
If there is activity on the 10Base-FL port, disconnect and reconnect
the 10Base-FL cable to restart the initialization process.
Verify that TX and RX cables on media converter are connected to
RX and TX ports, respectively, on other device.
Restart the workstation to restart the initialization process.
Contact Tech Support: (800) 260-1312, Int’l: 00-1-952-941-7600.
YES
Contact Tech Support: (800) 260-1312, Int’l: 00-1-952-941-7600.
11
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Contact Us
Technical Support
Technical support is available 24 hours a day.
US and Canada: 1-800-260-1312
International: 00-1-952-941-7600
Transition Now
Chat live via the Web with Transition Networks Technical Support.
Log onto www.transition.com and click the Transition Now link.
Web-Based Seminars
Transition Networks provides seminars via live web-based training.
Log onto www.transition.com and click the Learning Center link.
E-Mail
Ask a question anytime by sending an e-mail to our technical support staff.
techsupport@transition.com
Address
Transition Networks
6475 City West Parkway
Minneapolis, MN 55344, U.S.A.
telephone: 952-941-7600
toll free: 800-526-9267
fax: 952-941-2322
Declaration of Conformity
Name of Mfg: Transition Networks
6475 City West Parkway, Minneapolis MN 55344 U.S.A.
Model: CETTF10xx-105 Series Media Converters
Part Number(s): CETTF1011-105, CETTF1012-105, CETTF1013-105, CETTF1014-105,
CETTF1014-106, CETTF1015-105, CETTF1018-105, CETTF1022-105,
CETTF1027-105, CETTF1029-105, CETTF1029-106
Regulation: EMC Directive 89/336/EEC
Purpose: To declare that the CETTF10xx-105 to which this declaration refers is
in conformity with the following standards.
CISPR 22:1993; EN 55022:1994+A1:1995+A2:1997; EN 55024:1998 Class A; FCC
Part 15 Subpart B; EN 61000-3-2:1995; EN61000-3-3:1995
I, the undersigned, hereby declare that the equipment specified above conforms to the above
Directive(s) and Standard(s).
April, 12 2006_____
Stephen Anderson, Vice-President of Engineering Date