Trane XT302C Thermostat User Manual


 
8
XT302C DELUXE PROGRAMMABLE HEAT-COOL THERMOSTAT
69-1213—1 (T8624)
Pub. No. 18-HD25D7-5
2. Press Day until the current day displays.
NOTE: Sun=Sunday, Mon=Monday, Tue=Tuesday,
Wed=Wednesday, Thu=Thursday, Fri=Friday,
Sat=Saturday.
3. Press Time or Time until the current time displays.
NOTE: Tapping the Set Current Day/Time will change the
time in one hour increments.
NOTE: If the current time is Daylight Savings Time, press
Daylight Time until DST displays.
Fig. 13. Display of test number.
Refer to Table 5 for the directions and results of the specific tests.
NOTE: Press Time to advance to the next test and Time
to go back to the previous test. Press Run Program to
exit the self-test. This mode times out 5 minutes after
the last key press.
NOTE: Press Time to return to the previous test or Time
to advance to the next test.
NOTE: To exit, press Time or Time then Run Program.
Time
Set Program
SystemFilter Fan
Run
Program
Hold Temp
Set Current
Day/Time
Wake
Leave
Return Sleep
Day
Heat/Cool
Settings
Daylight
Time
Copy
M12954
Daylight
Time
AM
DST
Tue
Set Day/Time
M12955
Run
Program
Auto
System Fan
Wake
Room
AM
DST
Tue
Heat
Time
Set Program
SystemFilter Fan
Run
Program
Hold Temp
Set Current
Day/Time
Wake
Leave
Return Sleep
Day
Heat/Cool
Settings
Daylight
Time
Copy
Fig. 12. Display of all the segments of the LCD.
To start the self-test:
Press and hold the Increase and Decrease keys at the
same time until all display segments and the number 10
appears (all displays segments appear for approximately
three seconds before the test number displays). See
Figs. 12 and 13.
Table 4. Tests Available In The Installer Self-Test.
Aux Ht
Heat
Auto
System Fan
Off Auto
Wake
Mon
Wait
In
Room
Outdoor
Auto
Sav
AM
PM
Hold for
Cool
Repl Batt
On
Recovery
DST
Cool
TueWedThuFriSatSun
LeaveReturnSleep
M17111
Set Program
Set Day/Time
Start Time
Temporary Setting Enrg
Em
Heat
Em Ht
M10257A
TEST NUMBER
Time
Set Program
SystemFilter Fan
Run
Program
Hold Temp
Set Current
Day/Time
Wake
Leave
Return Sleep
Day
Heat/Cool
Settings
Daylight
Time
Copy
M12952
Day
PM
Tue
Set Day/Time
Time
Set Program
SystemFilter Fan
Run
Program
Hold Temp
Set Current
Day/Time
Wake
Leave
Return Sleep
Day
Heat/Cool
Settings
Daylight
Time
Copy
M12953
Time
AM
Tue
Set Day/Time
4. Press Run Program.
INSTALLER SELF-TEST
Use the Installer Self-Test to check the thermostat operation.
Refer to Table 4 for a list of the available self-tests.
CAUTION
Equipment Damage Hazard.
Equipment damage can occur if the compressor
is cycled too quickly.
The minimum off time is deactivated during the
Installer Self-Test.
Perform the test so that the compressor is cycled
slowly.
Test
Number Self-Test Description
10 Heating Equipment
30 Cooling Equipment
40 Fan Equipment
50 Comfort-R Terminals (H-H)
60 Keyboard Operation
70 Device Information