Trane XT302C Thermostat User Manual


 
XT302C DELUXE PROGRAMMABLE HEAT-COOL THERMOSTAT
5
69-1213—1 (T8624)
Pub. No. 18-HD25D7-5
IMPORTANT
Only configurable numbers display.
Example: Installer
Setup Number 1 does not display because it is not
configurable. Review the factory settings in Table 3
and make any desired changes in the Actual Settings
column. When the Installer Setup is complete, review
the settings to confirm that they match the system and
the boxes you checked in the Customizing Your
Thermostat chart located in the Owners Guide.
To advance to the next Installer Setup, press Time .
To change a setting, press Increase or Decrease .
To scroll the Installer Setup numbers backwards, press
Time .
To exit the Installer Setup, press Run Program.
CAUTION
Equipment Damage Hazard.
Can cause permanent equipment damage.
Electric heat systems must be configured to 1 in
Installer Setup number 2 to prevent equipment damage
caused by the system running without the fan.
Table 3. Installer Setup Options for the XT302C.
(continued)
Press Time
or
Press Increase or Decrease to change setting
Installer
Factory Setting Other Choices
Actual
Select
Setup Number
Display Description Display Description
Setting
Programming 42
Press Time to
bypass 2–41
and go directly
to setup #42
0 7-day programming 1 or 2 1—24-hour programming
2—No programming
Fan operation 2 0 Conventional
applications where
equipment
controls
fan operation in heat
mode
1 Applications where
thermostat
controls fan
operation in heat mode
Number of
heating Stages
3 2 2 heating stages 0 or 1 0—no heating
1—1 heating stage
Stage 1 heating
cycle
rate
4 3 3—3 cph
recommended 5, 6, or
9 cph not
recommended
5, 6, or 9 5—5 cph
6—6 cph
9—9 cph
Stage 2 heating
cycle
rate
5 5 5—5 cph
recommended
3, 6, or 9 cph not
recommended
3, 6, or 9 3—3 cph
6—6 cph
9—9 cph
Number of
Cooling Stages
8 1 1 cooling stage 0 or 2 0—no cooling
2—2 cooling stages
Stage 1 cooling
cycle rate
9 3 3—3 cph
recommended
2 or 5 cph not
recommended
2 or 5 2—2 cph
5—5 cph
Stage 2 cooling
cycle rate
10 3 3—3 cph
recommended
2 or 5 cph not
recommended
2 or 5 2—2 cph
5—5 cph
System setting
adjustment
12 0 Auto changeover 1 or 2 1—Manual changeover
2—Auto changeover only