Trane TWA200B Heating System User Manual


 
21
Performance
Data
SSP-PRC002-EN
(System)
Table PD-10 — Gross Heating Capacities (kW)
TWA100A Heat Pump with TWE100A Air Handler At 5649 m
3
/h (SI)
Outdoor Heating Capacity (kW) At Total Power in Kilowatts At
Temperature Indicated Indoor Dry Bulb Temperature Indicated Indoor Dry Bulb Temperature
(°C) 15.6 21.1 23.9 26.7 15.6 21.1 23.9 26.7
-27.8 6.0 10.9 12.1 12.8 5.5 6.0 6.2 6.5
-25.0 9.2 12.2 13.1 13.6 5.6 6.1 6.3 6.6
-22.2 11.4 13.5 14.2 14.6 5.7 6.2 6.5 6.7
-19.4 13.3 14.9 15.3 15.6 5.8 6.3 6.6 6.9
-16.7 15.2 16.3 16.6 16.8 5.9 6.5 6.7 7.0
-13.9 17 .0 17.7 17.9 18.0 6.0 6.6 6.9 7.2
-11.1 18.8 19.3 19.4 19.4 6.2 6.7 7.0 7.4
-8.3 20.6 20.9 20.9 20.9 6.3 6.9 7.2 7.5
-5.6 22.5 22.6 22.5 22.5 6.5 7.0 7.4 7.7
-2.8 24.5 24.4 24.3 24.1 6.6 7.2 7.5 7.9
0.0 26.5 26.3 26.1 26.0 6.8 7.4 7.7 8.1
2.8 28.6 28.2 28.0 27.8 6.9 7.6 7.9 8.3
5.6 30.6 30.1 29.9 29.7 7.1 7.8 8.1 8.5
8.3 32.8 32.2 31.9 31.7 7.3 8.0 8.4 8.8
11.1 35.0 34.3 34.0 33.7 7.5 8.2 8.6 9.0
13.9 37.2 36.5 36.2 35.9 7.7 8.4 8.8 9.2
16.7 39.5 38.7 38.3 38.0 7.9 8.7 9.1 9.5
19.4 41.7 40.9 40.5 40.2 8.1 8.9 9.3 9.8
22.2 44.1 43.2 42.8 42.4 8.4 9.2 9.6 10.0
Correction Factors - Other Airflows
(Table Value x Correction Factor = Value at new airflow)
Airflow 3000 cfm 3675 cfm
5097 m
3
/h 6243 m
3
/h
Heating Capacity x 0.99 x 1.01
Compressor kW x 1.02 x 0.98
Values at ARI Rating Conditions of:
70F (21.1C) and 47/43F (8.3/6.1C)(High Temp.Cond.)
70F (21.1C) and 17/15F (-8.3/-9.4C)(Low Temp. Cond)
Airflow = 3325 cfm (5649 m
3
/h)
Heating Capacity (High Temp.) = 110,000 (32.21)
Heating Capacity (Low Temp.) = 71,000 (20.79)
Compressor Power (High Temp) = 7.59 kW
Compressor Power (Low Temp) = 6.60 kW
Coeff. Of Perf. (High Temp) = 3.4
Coeff. Of Perf. (Low Temp) = 2.4
Outdoor Fan Power = 615 watts
Indoor Fan Power = 1,030 watts
Note:
1. Rated with 25 feet of 1-3/8" suction and 1/2" liquid line.
Table PD-10 — Gross Heating Capacities (MBh)
TWA100A Heat Pump with TWE100A Air Handler At 3325 CFM (I-P)
Outdoor Heating Capacity (Btu/1000) At Total Power in Kilowatts At
Temperature Indicated Indoor Dry Bulb Temperature Indicated Indoor Dry Bulb Temperature
(°F) 60707580 60707580
-18 20.4 37.3 41.2 43.6 5.7 7.3 7.9 8.5
-13 31.4 41.8 44.6 46.4 6.2 7.5 8.0 8.6
-8 39.0 46.3 48.4 49.7 6.5 7.6 8.1 8.6
-3 45.5 50.8 52.4 53.3 6.8 7.8 8.2 8.7
2 51.8 55.6 56.7 57.3 7.0 7.9 8.4 8.8
7 57.9 60.6 61.3 61.6 7.2 8.0 8.5 9.0
12 64.1 65.8 66.2 66.3 7.3 8.2 8.6 9.1
17 70 .4 71. 3 71. 4 71.3 7.5 8.3 8.7 9.2
22 76.9 77.1 77.0 76.7 7.6 8.4 8.9 9.4
27 83.6 83.3 82.9 82.5 7.8 8.6 9.0 9.5
32 90.7 89.7 89.2 88.7 7.9 8.8 9.2 9.7
37 97.6 96.2 95.5 94.9 8.1 8.9 9.4 9.9
42 104.6 102.9 102.1 101.4 8.2 9.1 9.6 10.1
47 112.0 109.9 109.0 108.2 8.4 9.3 9.7 10.3
52 119.5 117.2 116.2 115.2 8.6 9.5 10.0 10.5
57 127.1 124.6 123.5 122.5 8.8 9.7 10.2 10.7
62 134.8 132.1 130.8 129.7 9.0 9.9 10.4 11.0
67 142.6 139.7 138.3 137.2 9.2 10.1 10.7 11.2
72 150.7 147.5 146.1 144.8 9.4 10.4 10.9 11.5