Location and Preparation of Units
1. Select an appropriate position
that allows every corners of the
room to be uniformly air
conditioned and where it is easy
to route the refrigerant tubing.
2. Ensure that the floor or ceiling
construction is sufficient to fully
support the weight of the indoor
unit.
3. Consideration must be given to
assure an unobstructed flow of
supply and return air.
4. Refrigerant tubes between
indoor and outdoor units should
be as short as possible.
5. Length of the condensate drain
hose should be kept as short as
possible (Figure 1).
6. Recommended service
clearance as shown in figure
2, 3 and 4.
7. Do not install unit in direct
sunlight or near other heat
sources as this may affect
performance. Do not allow
outside air to directly enter unit
or condensate may form at the
unit’s discharge.
Note: For MCX042-MCX060 the
unit should be installed over the floor
at least 20 cm.
Figure 4
Figure 3
Figure 2
Maintenance area
(Celling mounted)
Min.
30 cm.
Min.
20 cm.
Min.
20 cm.
Min.
30 cm.
Min.
20 cm.
Maintenance area
(Floor mounted)
Figure 1
Min. 120 cm.
Min.
30 cm.
Min.
20 cm.
Min.
20 cm.
Maintenance area
(Low wall mounted)
MS-SVN015-EN.p65 6/27/07, 11:23 AM5