Performance Data Cooling
4YCY4036A1/3 AT 1200 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES)
OD ID TOT SENS CAP AT ENTERING DB TEMP TOTAL
AMB WB CAP 72 75 78 80 KW
85
59 34.5 28.8 32.4 34.5 34.5 2.7
63 36.0 23.4 27.0 30.5 32.9 2.7
67 38.8 18.5 22.0 25.6 27.9 2.8
71 41.9 13.5 17.1 20.6 23.0 2.8
95
59 32.0 27.6 31.2 32.0 32.0 3.0
63 33.4 22.3 25.9 29.4 31.8 3.1
67 35.9 17.4 20.9 24.5 26.9 3.1
71 38.8 12.4 16.0 19.6 21.9 3.1
105
59 29.5 26.5 29.5 29.5 29.5 3.3
63 30.7 21.2 24.8 28.4 30.7 3.4
67 33.1 16.3 19.9 23.4 25.8 3.4
71 35.7 11.4 15.0 18.5 20.9 3.4
115
59 26.9 25.4 26.9 26.9 26.9 3.6
63 28.1 20.2 23.7 27.3 28.1 3.7
67 30.2 15.3 18.8 22.4 24.8 3.7
71 32.7 10.4 13.9 17.5 19.9 3.7
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
AIR FLOW CAPACITY TOTAL POWER
RATE, CFM MULTIPLIER MULTIPLIER
LOW 1050 0.97 0.98
HIGH 1350 1.03 1.02
ARI RATING FOR COOLING
CFM CAPACITY (A) TEST SEER EER
1210 36000 14.20 11.60
ARI Standard Capacity Rating Conditions
ARI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F
WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High
Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air
entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering
outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating
is the same as for cooling.
4YCY4024A1 AT 800 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES)
OD ID TOT SENS CAP AT ENTERING DB TEMP TOTAL
AMB WB CAP 72 75 78 80 KW
85
59 22.9 19.1 21.4 22.9 22.9 1.8
63 23.9 15.6 17.9 20.2 21.8 1.8
67 25.8 12.3 14.7 17.0 18.6 1.9
71 27.8 9.1 11.5 13.8 15.3 1.9
95
59 20.9 18.2 20.5 20.9 20.9 2.0
63 21.8 14.7 17.0 19.3 20.9 2.0
67 23.5 11.5 13.8 16.1 17.7 2.0
71 25.3 8.3 10.6 12.9 14.5 2.0
105
59 18.8 17.3 18.8 18.8 18.8 2.1
63 19.6 13.8 16.1 18.5 19.6 2.1
67 21.1 10.6 12.9 15.3 16.8 2.2
71 22.8 7.4 9.7 12.1 13.6 2.2
115
59 16.7 16.4 16.7 16.7 16.7 2.3
63 17.5 13.0 15.3 17.5 17.5 2.3
67 18.8 9.8 12.1 14.4 16.0 2.3
71 20.3 6.6 8.9 11.2 12.8 2.3
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
AIR FLOW CAPACITY TOTAL POWER
RATE, CFM MULTIPLIER MULTIPLIER
LOW 700 0.97 0.98
HIGH 900 1.03 1.02
ARI RATING FOR COOLING
CFM CAPACITY (A) TEST SEER EER
790 23400 14.00 11.60
ARI Standard Capacity Rating Conditions
ARI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F
WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High
Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air
entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering
outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating
is the same as for cooling.
4YCY4030A1 AT 1000 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES)
OD ID TOT SENS CAP AT ENTERING DB TEMP TOTAL
AMB WB CAP 72 75 78 80 KW
85
59 29.8 24.1 26.9 29.2 28.9 2.3
63 31.0 19.7 22.6 25.5 27.4 2.3
67 33.4 15.8 18.6 21.5 23.4 2.3
71 36.1 11.8 14.6 17.5 19.4 2.3
95
59 27.3 23.0 25.8 27.3 27.3 2.5
63 28.5 18.7 21.5 24.4 26.3 2.5
67 30.7 14.7 17.6 20.4 22.3 2.5
71 33.1 10.7 13.6 16.5 18.4 2.5
105
59 24.8 21.9 24.7 24.8 24.8 2.7
63 25.9 17.6 20.5 23.3 25.2 2.7
67 27.9 13.7 16.5 19.4 21.3 2.7
71 30.1 9.7 12.6 15.4 17.4 2.7
115
59 22.4 20.8 22.4 22.4 22.4 2.9
63 23.3 16.6 19.5 22.3 23.3 2.9
67 25.1 12.7 15.5 18.4 20.3 2.9
71 27.1 8.7 11.6 14.4 16.4 2.9
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
AIR FLOW CAPACITY TOTAL POWER
RATE, CFM MULTIPLIER MULTIPLIER
LOW 875 0.97 0.98
HIGH 1125 1.03 1.02
ARI RATING FOR COOLING
CFM CAPACITY (A) TEST SEER EER
890 30000 14.00 12.00
ARI Standard Capacity Rating Conditions
ARI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F
WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High
Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air
entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering
outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating
is the same as for cooling.