6
General Data
MODEL
RATED Volts/PH/Hz
Performance Cooling BTUHj
Indoor Airflow (CFM)
Power Input (KW)
EER/SEER(BTU/Watt-Hr.)n
Sound Power Rating [dB(A)]8
Performance Heatingk
Input BTUH - 1st Stage (Natural Gas)p
Input BTUH - 2nd Stage (Natural Gas)p
AFUE
Temp. Rise — Min/Max (°F)
Orifice Qty / Drill Size (Natural Gas)l
POWER CONN.—V/PH/HZ
Min. Brch. Cir. Ampacitym
Fuse Size — Max. (amps)
Fuse Size — Recmd. (amps)
COMPRESSOR
Volts/Ph/Hz
R.L. Amps — L.R. Amps
OUTDOOR COIL — TYPE
Rows/F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
INDOOR COIL — TYPE
Rows/F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
Refrigerant Control
Drain Conn. Size (in.)
OUTDOOR FAN — TYPE
Dia. (in.)
Drive/No. Speeds
Motor — HP/R.P.M.
Volts/Ph/Hz
F.L. Amps/L.R. Amps
INDOOR FAN — TYPE
Dia x Width (in.)
Drive/No. Speeds
CFM @ 0.0 in. w.g.n
Motor — HP/R.P.M.
Volts/Ph/Hz
F.L. Amps/L.R. Amps
COMBUSTION FAN — TYPE
Drive/No. Speeds
Motor — HP/R.P.M.
Volts/Ph/Hz
FLA
FILTER / FURNISHED
Type Recommended
Recmd. Face Area (sq. ft.)o
REFRIGERANT
Charge (lbs.)m
GAS PIPE SIZE (in.)
DIMENSIONS
Crated (in.)
WEIGHT
Shipping (lbs.) / Net (lbs.)
4YCY4036A3075A
208-230/3/60
36000
1210
3.284
11.6 / 14.2
69
56250
75000
80.0
30 / 60
2 / #33
208-230/3/60
19.8
30
30
SCROLL
208-230/3/60
11.5 / 77
SPINE-FIN
2 / 24
15.49
3/8
PLATE FIN
4 / 15
3.54
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
23.4
DIRECT / 1
1/5 / 830
208-230/1/60
1.1 / 1.9
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERF TABLE
1/2 / VARIABLE
200-230/1/60
4.3 / 4.3
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34
NO
THROWAWAY
4.0
R410A
6.75
1/2
H X W X L
47.86 / 44.5 / 52.03
488 / 392
4YCY4036A3096A
208-230/3/60
36000
1210
3.284
11.6 / 14.2
69
72000
96000
80.0
40 / 70
3 / #37
208-230/3/60
19.8
30
30
SCROLL
208-230/3/60
11.5 / 77
SPINE-FIN
2 / 24
15.49
3/8
PLATE FIN
4 / 15
3.54
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
23.4
DIRECT / 1
1/5 / 830
208-230/1/60
1.1 / 1.9
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERF TABLE
1/2 / VARIABLE
200-230/1/60
4.3 / 4.3
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34
NO
THROWAWAY
4.0
R410A
6.75
1/2
H X W X L
47.86 / 44.5 / 52.03
493 / 397
4YCY4042A1096A
208-230/1/60
42000
1350
3.5
12.0 / 14.25
74
72000
96000
80
30 / 60
3 / #37
208-230/1/60
31.5
50
50
SCROLL
208-230/1/60
18.6 / 105
SPINE-FIN
2 / 24
23.57
3/8
PLATE FIN
3 / 15
5
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
1/4 / 825
208-230/1/60
1.5 / 3.4
CENTRIFUGAL
11 X 10
DIRECT / VARIABLE
SEE FAN PERF TABLE
3/4 / VARIABLE
208-230/1/60
6.8 / 6.8
CENTRIFUGAL
DIRECT / 2
1/45 / 2800/1500
208-230/1/60
0.34
NO
THROWAWAY
5.3
R410A
6.8125
1/2
H X W X L
47.86 / 47.4 / 61.75
653 / 525
11
11
1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on ARI Standard 210/240. Noise calculated in accordance with A.R.I.
Standard 270.
22
22
2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation.
33
33
3 Convertible to LPG.
44
44
4 This value is approximate. For more precise value, see Unit Nameplate.
55
55
5 Based on U.S. Government Standard Tests.
66
66
6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation
with a clean resistance of 0.05" W.C.
77
77
7 Unit is shipped on high input, unit is convertible to low input with a Low Fire accessory kit.
88
88
8 Sound Power values are not adjusted for ARI 270-95 tonal corrections.