Trane 2TTA3030A3000A Fan User Manual


 
22-1770-01-1205 (EN) 31
CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)
MBTUH MBTUH SYST
INDOOR MODEL CFM TOT SEN KW
CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)
MBTUH MBTUH SYST
INDOOR MODEL CFM TOT SEN KW
Performance Data
Cooling
TXH041A4+TYATXV-3+*UD060R9V3 NOMINAL 1200 1.00 1.00 1.00
LOW 1059 0.98 0.98 0.99
HIGH 1361 1.02 1.02 1.01
TXH041A4+TYATXV-3+*UD080R9V3 NOMINAL 1200 1.00 1.00 1.00
LOW 1050 0.98 0.98 0.99
HIGH 1350 1.02 1.02 1.01
TXH041A4+TYATXV-3+*UD080R9V4 NOMINAL 1200 1.00 1.00 1.00
LOW 1033 0.98 0.98 0.99
HIGH 1328 1.02 1.02 1.01
TXH041A4+TYATXV-3+*UD100R9V3 NOMINAL 1200 1.00 1.00 1.00
LOW 1076 0.98 0.98 0.99
HIGH 1384 1.02 1.02 1.01
2TTA3036A3/4
TXH041A4+TYATXV-3+*UD100R9V5 NOMINAL 1200 1.00 1.00 1.00
LOW 1059 0.98 0.98 0.99
HIGH 1361 1.02 1.02 1.01
TXH041A4+TYATXV-3+*UY060R9V3 NOMINAL 1200 1.00 1.00 1.00
LOW 928 0.98 0.98 0.99
HIGH 1193 1.02 1.02 1.01
TXH041A4+TYATXV-3+*UY080R9V3 NOMINAL 1200 1.00 1.00 1.00
LOW 901 0.98 0.98 0.99
HIGH 1159 1.02 1.02 1.01
2TTA3042A3/4
2TTA3042A3/4 WITH 2TXCB042AC3 AT 1199 CFM
O.D. I.D. TOT. SENS. CAP. AT ENTERING D.B. TEMP. TOTAL
D.B. W.B. CAP. 72 75 78 80 KW
59 36.8 22.6 27.2 31.7 34.7 3.06
85 63 38.3 20.7 24.9 29.1 31.8 3.08
67 41.3 17.9 21.5 25.1 27.4 3.13
71 44.6 14.8 17.9 20.8 22.8 3.16
59 34.7 21.8 26.2 30.6 33.4 3.29
95 63 36.1 20.0 24.1 28.1 30.7 3.31
67 39.0 17.3 20.8 24.2 26.5 3.36
71 42.1 14.3 17.2 20.1 22.0 3.39
59 32.6 21.0 25.2 29.4 32.1 3.51
105 63 34.0 19.2 23.1 27.0 29.5 3.54
67 36.6 16.6 20.0 23.3 25.4 3.60
71 39.5 13.8 16.6 19.3 21.1 3.63
59 30.5 20.1 24.1 28.1 30.5 3.74
115 63 31.8 18.4 22.1 25.8 28.2 3.77
67 34.3 15.9 19.1 22.3 24.3 3.83
71 37.0 13.2 15.8 18.5 20.2 3.86
CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR)
AIRFLOW TOTAL CAPACITY SENSIBLE CAPACITY
LOW 1049 0.98 0.98
HIGH 1349 1.02 1.02
NOTE: ALL TABLES ABOVE ARE AT ARI RATING CONDITIONS RATED WITH 25 FEET OF REFRIGERANT LINES.
* DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY)
TOTAL CAPACITY, COMP. KW AND APP. DEW PT. ARE VALID ONLY FOR WET COIL. ALL TEMPERATURES IN DEGREES F.
CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)
MBTUH MBTUH SYST
INDOOR MODEL CFM TOT SEN KW
2CXAB042AC3 NOMINAL 1199 1.00 1.00 1.00
LOW 1094 0.98 0.98 0.99
HIGH 1406 1.02 1.02 1.01
2CXAB042AC3+*UD080R9V4 NOMINAL 1199 1.00 1.00 1.00
LOW 1225 0.98 0.98 0.99
HIGH 1575 1.02 1.02 1.01
2CXAB048AC3 NOMINAL 1199 1.00 1.00 1.00
LOW 1068 0.98 0.98 0.99
HIGH 1373 1.02 1.02 1.01
CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR)
MBTUH MBTUH SYST
INDOOR MODEL CFM TOT SEN KW
2CXAB048AC3+*UD080R9V4 NOMINAL 1199 1.00 1.00 1.00
LOW 1225 0.98 0.98 0.99
HIGH 1575 1.02 1.02 1.01
2CXAC043AC3 NOMINAL 1199 1.00 1.00 1.00
LOW 1225 0.98 0.98 0.99
HIGH 1575 1.02 1.02 1.01
2CXAC043AC3+*DY100R9V4 NOMINAL 1199 1.00 1.00 1.00
LOW 1076 0.98 0.98 0.99
HIGH 1384 1.02 1.02 1.01
2CXAC043AC3+*UY100R9V4 NOMINAL 1199 1.00 1.00 1.00
LOW 1068 0.98 0.98 0.99
HIGH 1373 1.02 1.02 1.01
2CXAC049AC3 NOMINAL 1199 1.00 1.00 1.00
LOW 1225 0.98 0.98 0.99
HIGH 1575 1.02 1.02 1.01
2CXAC049AC3+*DY100R9V4 NOMINAL 1199 1.00 1.00 1.00
LOW 1076 0.98 0.98 0.99
HIGH 1384 1.02 1.02 1.01
2CXAC049AC3+*UY100R9V4 NOMINAL 1199 1.00 1.00 1.00
LOW 1068 0.98 0.98 0.99
HIGH 1373 1.02 1.02 1.01
2CXAD050AC3 NOMINAL 1199 1.00 1.00 1.00
LOW 1225 0.98 0.98 0.99
HIGH 1575 1.02 1.02 1.01
2CXAD050AC3+*DD120R9V5 NOMINAL 1199 1.00 1.00 1.00
LOW 1234 0.98 0.98 0.99
HIGH 1586 1.02 1.02 1.01
2CXAD050AC3+*DY120R9V5 NOMINAL 1199 1.00 1.00 1.00
LOW 1068 0.98 0.98 0.99
HIGH 1373 1.02 1.02 1.01
2CXAD050AC3+*UD120R9V5 NOMINAL 1199 1.00 1.00 1.00
LOW 1216 0.98 0.98 0.99
HIGH 1564 1.02 1.02 1.01
2CXAD050AC3+*UD140R9V5 NOMINAL 1199 1.00 1.00 1.00
LOW 1208 0.98 0.98 0.99
HIGH 1553 1.02 1.02 1.01
2CXAD050AC3+*UY120R9V5 NOMINAL 1199 1.00 1.00 1.00
LOW 1059 0.98 0.98 0.99
HIGH 1361 1.02 1.02 1.01