Toshiba TCB-BC1602UUL Air Conditioner User Manual


 
Toshiba
–2–
Air-dischage direction kit
Installation Manual
EN
3 INSTALLATION METHODS
CAUTION
Before installing the wind shield, change the air conditioner settings. Refer to “Changing the setting” on page 4.
Unless the setting is changed, the air blow temperature becomes low. This may cause the dew condensation.
Installing the wind shield(s) and packings
Attach the wind shields to the air flow openings (made of styrene foam) of the indoor unit and place the packings
on them to block the air flow. (Refer to Fig. 1 to 3.)
Put the packings bending along the edges of the indoor unit external surface without blocking the concaved
portions of the drain pans. (If the packings are not put bending along the edge of the indoor unit external surface,
the dew condensation may occur.) (Refer to Fig. 1 and 3.)
* The size adjustment is required for the packing which are attached on the wind shield C. Cut 1.58” (40 mm) to
adjust its size in 16.5” x 4.3” (420 mm x 110 mm).
(Fig. 1) (Fig. 2)
(Fig. 3)
Packing Wind shield (A, B, C) Drain pan
Indoor
unit
External
surface
Interior styrene foam Air flow outlet
Packing
Packing
Wind shield B
Wind shield A
Packing
(required to cut
1.58” (40 mm.)
Wind shield C
Drain piping
Refrigerant piping
Wind shield A
Put the packings without
blocking the concaved
portions.
0.4” (10 mm)
0.4” (10 mm)
2-EN
+00EH99678401.BOOk Page 2 Friday, November 13, 2009 2:38 PM