Toshiba RAV-SP360AT2-UL Air Conditioner User Manual


 
– 64 –
Check crushed or broken pipe.
Defect Correct and Replace
Correct defective position.
Replace defective part.
Open valve fully.
Repair defectives position.
Recharge refrigerant.
Check outdoor P.C. board.
Defect Replace
Correct connector.
Case thermostat error Replace
Cut jumper line according
to the explanation sheet packaged
with the service P.C. board.
Is valve fully opened?
Is PMV normal?
Is there no gas leak?
Is it not refrigerant shortage?
Are CN609 connection
and case thermostat normal?
Is cooling/heating operation
available when short-circuiting
case thermostat?
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
CODE
No.
[H04]
[L10]
Outdoor
LED display
<Display 1> <Display 2>
ll
ll
¡
l
l
¥
¡
l
¡¡
<Display 1> <Display 2>
ll
¡ ¥
¡
l
l
¥
¡
l
¡¡
Check and troubleshooting
(Item without special mention Indicates part of outdoor unit.)
[Case thermostat operation]
[Unset model type]: Only when service P.C. board is used
<Display 1> <Display 2>
l
¥
¡
l
¡ ¥
l
¥
¡ ¥
¡¡
<Display 1> <Display 2>
¡ ¥
¡ ¥
¡ ¥
ll
¡
l
¡¡
[Communication error between MCU]
[Heat sink temp. sensor (TH) error] Refer to [F13] column.
There is a possibility that it is one of the following errors.
Confirm LED on outdoor P.C. board to judge which error it is.
Communication error between MCU, Heat sing temp. sensor (TH) error, EEPROM error,
Unset model type, Heat sink overheat error, Gas leak detection, 4-way valve inverse error
[L29]
Check outdoor P.C. board.
Defect Replace