– 32 –
5. SPECIFICATIONS OF ELECTRICAL PARTS
5-1. Indoor Unit
RAV-SM564UT-E, RAV-SM804UT-E
RAV-SM1104UT-E, RAV-SM1404UT-E
No.
1
2
3
4
5
6
Parts name
Fan motor (for indoor)
Thermo. sensor (TA-sensor)
Heat exchanger sensor (TCJ-sensor)
Heat exchanger sensor (TC-sensor)
Float switch
Drain pump motor
Type
SWF-230-60-2R
328 mm
Ø6 mm, 1000 mm
Ø6 mm, 950 mm
FS-0218-102
MDP-1401
Specifications
Output (Rated) 60 W
10 kΩ at 25°C
10 kΩ at 25°C
10 kΩ at 25°C
No.
1
2
3
4
5
6
Parts name
Fan motor
Thermo. sensor (TA-sensor)
Heat exchanger sensor (TCJ-sensor)
Heat exchanger sensor (TC-sensor)
Float switch
Drain pump motor
Type
ICF-280-150-1
328 mm
Ø6 mm, 1000 mm
Ø6 mm, 950 mm
FS-0218-102
MDP-1401
Specifications
Output (Rated) 90 W
10 kΩ at 25°C
10 kΩ at 25°C
10 kΩ at 25°C
5-2. Outdoor Unit (Parts Ratings)
RAV-SP1104AT-E, RAV-SP1404AT-E / RAV-SP1104ATZ-E, RAV-SP1404ATZ-E /
RAV-SP1104ATZG-E, RAV-SP1404ATZG-E
5-3. Accessory Separate Sold Parts
RBC-U31PG(WS)-E, RBC-U31PG(W)-E (Ceiling panel)
RAV-SM564UT-E, RAV-SM804UT-E, RAV-SM1104UT-E, RAV-SM1404UT-E
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Parts name
Compressor
Outdoor fan motor
Reactor
4-way valve coil
PMV coil
P.C. board
Fuse (Mounted on P.C. board)
Fuse (Mounted on P.C. board)
Fuse (Mounted on P.C. board)
Outdoor temp. sensor (TO sensor)
Heat exchanger sensor (Te sensor)
Discharge temp. sensor (Td sensor)
Heat exchanger mid. Temp sensor (TL sensor)
Compressor thermo. (Protection)
Type
DA422A3F-25M
ICF-280-A100-1
CH-62
VHV-01AP552B1
UKV-A038
MCC-1571
—
—
—
—
—
—
—
US-622
Specifications
—
Output 100W
5.7mH, 18.5A
AC240V
DC12V
AC220 – 240V
AC250V, 25A
AC250V, 10A
AC250V, 3.15A
10 kΩ at 25°C
10 kΩ at 25°C
50 kΩ at 25°C
10 kΩ at 25°C
OFF: 125 ± 4°C, ON: 90 ± 5°C
No.
1
2
Parts name
Motor-louver
Type
MP24ZN3N
Specifications
DC 12 V