Louver control:
In case of 4-way
Discharge
Cassette type
Outline of specifications
1) Louver position setup
• When the louver position is changed, the position moves
necessarily to downward discharge position once to return to
the set position.
•
The louver position can be set up in the following operation range.
In cooling/dry operation In heating/fan operation
• In group twin/triple operation, the louver positions can be set
up collectively or individually.
2) Swing setup
• [SWING] is displayed and the following display is repeated.
In all operations
• In group twin operation, the louver positions can be set up
collectively or individually.
3) When the unit stopped or the warning was output, the louver is
automatically set to full closed position.
4) When PRE-HEAT
(Heating ready) is displayed
(Heating operation started or defrost operation is performed),
heating thermo is off or self-cleaning is performed, the louver is
automatically set to horizontal discharge position.
∗ The louver which air direction is individually set or the locked
louver closes fully when the unit stops and the louver is
automatically set to horizontal discharge position when
PRE-HEAT
(Heating ready) is displayed, heating thermo is
off or self-cleaning is performed.
<<Individual air direction setup>>
• Pushing
UNIT LOUVER
Louver select button enables every discharge
port to set up the air direction.
• In case of no input (key operation) for approx. 5 seconds during
setting of individual air direction (during displaying of louver No. on
the remote controller screen), the remote controller screen returns to
the normal display screen.
• For the air direction illustration during normal operation, the air
direction of the least No. among the louvers which are block-set is
displayed.
• While individual air direction is being set, the remote controller
operation (Illustration of air direction) and operation of the real
machine are linked.
• When selecting a case,
UNIT LOUVER
Louver select button is not
pushed or louver No. is not
displayed, the air directions
of all the louvers are
collectively set up.
Remarks
The louver position
at horizontal
discharge position
at under SM80
differs from that at
over SM110.
The swinging
louver moves
usually up to the
ceiling side from
the louver position
of the set time.
Setup from the
remote controller
without
UNIT LOUVER
but-
ton is unavailable.
For the setup
operation, refer to
“How to set up
louver individually”
of Item “Setup at
local site/Others”.
Using same as the
present 4-way Air
Discharge Cassette
Type is possible