Toshiba RAV-SP1102UT-E Air Conditioner User Manual


 
– 35 –
Indoor unit
Outdoor unit
TCJ
sensor
Air heat exchanger
Strainer
Strainer
TC sensor
Packed valve
Outer dia. ØA
Packed valve
Outer dia. ØB
Max.
50m
Min.
5m
TS sensor
Accumulator
(1500cc)
TD sensor
TO sensor
TE
sensor
4-way valve
(STF-0213Z)
Ø25 × L160
Rotary compressor
(DA220A2F-20L1)
Heat exchangerØ8
1 row 30 stages
FP1.3 flat fin
Capillary
Ø3×Ø2×
L530
Ø25 × L210
Muffler
R410A 1.5 kg
Cooling
Heating
Modulating
(PMV)
(CAM-B30YGTF-2)
Refrigerant pipe
at gas side
Outer dia. ØA
Refrigerant pipe
at liquid side
Outer dia. ØB
* The refrigerating cycle of the indoor units differs according to
the models to be combined. For the refrigerating cycles of the
other indoor units, refer to the corresponding Service Manuals
described in the list on the cover.
Outer diameter of refrigerant pipe
Gas side ØA Liquid side ØB
12.7mm 6.4mm
Height difference (m)
Outdoor unit
at upper side
Outdoor unit
at lower side
30 15
Height
difference
Section shape
of heat insulator
RAV-SM563UT-E, RAV-SM562BT-E, RAV-SM562CT-E / RAV-SP562AT-E
*
4 poles are provided to this compressor.
The compressor frequency (Hz) measured with a clamp meter is 2 times of revolutions (rps) of the compressor.
Standard
Cooling Overload
Low load
Standard
Heating Overload
Low load
Pressure
(MPa)
Pd Ps
2.71 1.03
3.48 1.16
1.92 0.74
2.22 0.72
3.47 1.16
1.79 0.25
Pipe surface temperature (°C)
Discharge
(TD)
75
81
34
32
81
71
Suction
(TS)
15
20
5
6
20
16
Indoor heat
exchanger
(TC)
10
16
2
38
55
30
Outdoor heat
exchanger
(TE)
38
51
11
2
15
18
Compressor
revolutions per
second (rps)
*
43
44
24
41
41
70
Indoor
fan
HIGH
HIGH
LOW
HIGH
LOW
HIGH
Indoor/Outdoor
temp. conditions
(DB/WB) (°C)
Indoor Outdoor
27/19 35/–
32/24 43/–
18/15.5 –5/–
20/– 7/6
30/– 24/18
15/–
–15/(70%)