15-4.2. Replacement Procedure of Service Main P.C. Board
Replacement Procedure of Indoor Control P.C. Board
(AIK-PXXXH series, SIK-PXXXH series)
For this indoor control P.C. board [AIK/SIK-P SERVICE] corresponding to the common P.C. boards, follow to this
replacement procedure when replacing P.C. board.
(When using SIK-PXXXH series, P.C. board name, parts layout, etc. of the presently mounted P.C. board differ
from those of this service P.C. board. However there is no problem in the functions.)
Components
Service P.C. board (MCC-1370A [AIK/SIK-P SERVICE] : 1 unit
Replacement Procedure of Indoor Control P.C. Board : These sheets
Replacement Record of remote controller/indoor control P.C. board/outdoor control P.C. board : 1 sheet
Replacement Procedure
1
Remove the presently mounted P.C. board from the electric parts box.
(Be sure to send back the replaced P.C. board with Replacement Record attached separately.)
2
Set Dip SW and jumpers of the service P.C. board according to the following exchange correspon-
dence table.
As it is : Setup of jumper of the service P.C. board is not changed.
3
Mount P.C. board according to [Mounting].
Model
Part
SW03
1
2
J01
J07
J09
J11
J12
J14
J15
J16
J17
J19
J22
J24
J25
J36
J50
J53
J54
J55
<Reference>
Service P.C. board
Initial setup
at shipment
ON
OFF
AIK-PXXXH series
AIK-P400H AIK-P630H AIK-P710H
AIK-P450H AIK-P800H
AIK-P500H
AIK-P560H
Match setup with one of former P.C. board.
As it is :
Match setup with one of former P.C. board.
As it is :
As it is : As it is : Cut :
As it is : Cut : As it is :
As it is : As it is : As it is :
As it is :
As it is :
Cut :
As it is :
As it is :
As it is :