Toshiba RAS-M14EACV-E Air Conditioner User Manual


 
– 46 –
Item
9. Louver control
1) Louver
position
Operation flow and applicable data, etc.
This function controls the air direction of the indoor unit.
The position is automatically controlled according to the operation
mode (COOL/HEAT).
The set louver position is stored in memory by the microcomputer,
and the louver returns to the stored position when the next opera-
tion is performed. (Cooling/heating memory position)
The angle of the louver is indicated as the horizontal angle is 0°.
When the louver closes fully, it directs approx. 49° upward.
1) Louver position in cooling operation
Description
Swing operation is performed in width 35° with the stop position as
the center.
If the stop position exceeds either upper or lower limit position,
swing operation is performed in width 35° from the limit which the
stop position exceeded.
2) Air direction
adjustment
3) Swing
2) Louver position in heating operation
Swing
When pushing [SWING]
button during operation,
the louver starts swing-
ing.
The louver position can
be arbitrarily set up by
pushing [FIX] button.
Louver
angle
Horizontal
(0˚)
Horizontal
blowing
Inclined
blowing
Blowing
downward
Air direction
Inclined
blowing
Horizontal
blowing
Cooling operation/
AUTO (COOL)/Dry
Hi Power
Room temp. (Ta) <
Set temp. (Tsc) + 3.5
Room temp. (Ta)
Set temp. (Tsc) + 3.5
Initial setting of
“Cooling storage position”
Louver :
Directs downward (9˚)
Initial setting of
“Cooling storage position”
Louver :
Directs downward (9˚)
“Inclined blowing”
Louver :
Directs downward (14˚)
Heating operation/
AUTO (HEAT)
ECO operation
Room temp. (Ta) <
Set temp. (Tsc) – 3 or
25 minutes after start
of operation
Room temp. (Ta)
Set temp. (Tsc) – 3
Initial setting of
“Heating storage position”
Louver :
Directs downward (76˚)
“Heating storage position”
Louver :
Directs downward (76˚)
“Cooling storage position”
Louver :
Directs downward (9˚)
Cooling/AUTO
(COOL)/DRY
operation
Powerful
operation
Cooling
memory
position
Inclined
blowing
Cooling
memory
position
Room temp.
Set temp. +3.5
Room temp.
Set temp. +3.5
Heating
operation
YES
YES
YES
YES
NO
NO
YES
YES
NO
NO
NO
NO
ECO
operation
Heating
memory
position
Horizontal
position
Heating
memory
position
Room temp.
Set temp. –3.0
Room temp.
Set temp. –3.0