9.2 Motor Lubrication
Oil the unit every six months with 3 - 4 drops of SAE 20
weight non-detergent oil. Lubricate the motor with a drop of
oil after each washing.
IMPORTANT: The approved oil for lubrication is SAE 20
weight non-detergent oil, specifically designated for use
with electric motors.
9.3 Cleaning
The housing is made of a durable and washable
polyethylene. When cleaning, the use of solvents is NOT
recommended.
When washing inside the unit, disconnect the unit from its
power source. Protect the operator interface panel with
a cloth. Clean inner barrel, grills and blade. Wipe down
motor exterior with a damp cloth. If the motor gets wet
during cleaning, simply allow ample time for motor to dry
out completely before restarting. If you clean your device
frequently perform motor lubrication more frequently as
well.
If you wash the Axial Air Mover and do not plan to use it
within 24 hours, allow the fan to drip dry for 10 minutes
and then let run for 5 minutes. Before storing it, apply oil
as described above.
10 Replacement Parts and
Optional Accessories
Contact the factory at 1-800-533-7533 to order
replacement parts, or optional accessories
4025203 Breaker, CKT, 12A
4025204 Switch, Rocker, On-Off-On
4025205 Outlet, Duplex, GFCI, 15A
4025206 Grill, Safety, Intake
4025207 Grill, Safety, Exhaust
4025460 Axial Air Mover Stand
4025299 Stand Hardware Kit
Figure 11: Optional stand
allows the Axial Air Mover’s
air flow to be directed in a
360° range of movement.
(PN 4025460)
11 Wiring Diagram
Specifications subject to change without notice.