State Industries SUF 100 THRU 250 Water Heater User Manual


 
10
Servicing should only be performed by a Qualied Service Agent
INSTALLATION – VENTING CATEGORY AND MATERIALS
ULTRA FORCE VENTING
Category IV Positive pressure in vent, above atmospheric.
These models will produce excessive condensate in vent.
Vent system must not be combined with any other appliances.
Flue gas temperatures less than 140°F.
Condensing water heater, thermal efficiency of this product will produce condensate in
the vent system, the heater is equipped with provision for draining condensate from vent
system.
PH of condensate approximately 3.59; within tolerance for cast iron drains.
Type venting May be installed Direct Vent; draws all fresh air for combustion from and discharges flue
gases to the outdoor atmosphere through 2 pipes.
May be installed Conventional Vent; uses room air for combustion and discharges flue
gases to the outdoor atmosphere through 1 pipe.
Vertical and horizontal Vent system can be terminated vertically or horizontally (side wall).
Vent materials PVC schedule 40.
CPVC schedule 40.
ABS schedule 40.
Cellular Core PVC.
Concentric Venting Concentric vent kits for all models.