SBN TANK TYPE COMMERCIAL GAS WATER HEATER
SERVICE HANDBOOK
TEST 8 - IGNITER HEATS – NO MAIN BURNER
Conditions:
Plugs in receptacle
Igniter energizes (gets red)
No main burner or main shuts off within 5 seconds.
Note flash code of LED.
TEST 8
Test of Igniter and gas valve circuit
If… ...then
short heat up time of igniter
check control box grounding
normal (Approximate 20 seconds)
warm up - no ignition
check for 24V from E1, Pin 12 to ground during 4
second trial.
- Yes - Continue
- No - Replace Igntion Board
no voltage present
E4, Pin 12 to
ground
replace ignition board
24 Volt
was present
from E1, Pin
12 to ground, but no main burner
check that air has been purged from gas circuit
check that wiring and connections to gas valve and
E1, Pin 9 are correct
check for 24 VAC at E1, Pin 9 to ground during 4
second trial
24
24
E1 Plug, Pin 9
Plug in Receptacle
E1 Plug, Pin 12
Plug in Receptacle
Pin 12
Pin 9